Agilent Technologies 6811B, 6834B, 6814B, 6843A manual STATus:QUEStionable:INSTrument:ISUMmary:ENABle

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 100
Image 100

3 - Language Dictionary

STATus:QUEStionable:INSTrument:ISUMmary:CONDition?

Agilent 6834B Only

Phase Selectable

This query returns the value of the Questionable Condition register for a specific output of a three-phase ac source. The particular output phase must first be selected by INST:NSEL.

The Condition register is a read-only register which holds the real-time (unlatched) questionable status of the ac source.

Query Syntax

STATus:QUEStionable:INSTrument:ISUMmary:CONDition]?

Parameters

None

Examples

STAT:QUES:INST:ISUM:COND?

Returned Parameters

<NR1> (register value)

Related Commands

STAT:QUES:COND?

STATus:QUEStionable:INSTrument:ISUMmary:ENABle

Agilent 6834B Only

Phase Selectable

This command sets or reads the value of the Questionable Enable register for a specific output of a three- phase ac source. The particular output phase must first be selected by INST:NSEL.

The Enable register is a mask for enabling specific bits from the Questionable Event register to set the questionable summary (QUES) bit of the Status Byte register. This bit (bit 3) is the logical OR of all the Questionable Event register bits that are enabled by the Questionable Status Enable register.

Command Syntax

STATus:QUEStionable:INSTrument:ISUMmary:ENABle <NRf+>

Parameters

0 to 32767 MAXimum MINimum

Default Value

0

Examples

STAT:QUES:INST:ISUM:ENAB 32

Query Syntax

STATus:QUEStionable:INSTrument:ISUMmary:ENABle?

Returned Parameters

<NR1> (register value)

Related Commands

STAT:QUES:INST:ISUM?

100

Page 100
Image 100
Agilent Technologies 6811B, 6834B, 6814B, 6843A STATus:QUEStionable:INSTrument:ISUMmary:ENABle, Stat:Ques:Inst:Isum:Cond?