Agilent Technologies 6834B, 6814B, 6811B SYSTem:CONFigure, Agilent 6812B, 6813B, 6843A Only

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 179
Image 179
Manual background

IEC Mode Command Summary - E

SYSTem:CONFigure

Agilent 6812B, 6813B, 6843A Only

This command sets the overall operating mode of the ac source. The choices are Normal mode, which causes the product to closely mimic the operating characteristics of standard ac sources, or IEC mode, which modifies the basic behavior of the transient and measurement systems to facilitate IEC measurements. SYSTem:CONFigure has a variety of global consequences that are summarized below:

Base Sampling Rate

Output Frequency

Freq/Window/Fs Mode

Transient System

NORMAL MODE

39.920792 KHz

DC - 1000 Hz

Independent

FIXEd/STEP/PULSe/LIST Modes

IEC MODE

38.400000 KHz

50 Hz & 60 Hz Only

Coupled

FIXEd Mode Only

Slew Operation

MEASure:ARRay:CURRent

:HARM?

CALCulate:SMOothing

MEASure:ARRay:VOLTage

:FLUCtuations

CALCulate:INTegral:TIME

AC & DC Voltage; Frequency

DC, Fundamental, and Harmonics to 50th

Not/Available

Not/Available

Not/Available

AC Voltage Only

Fundamental and Harmonics to 40th plus RMS Current, RMS Voltage & Real Power

1.5Second Smoothing on/off FLICker PST ALL?

1 5 10 15 MINutes

Transmission of a SYSTem:CONFigure command implies ABORt and terminates any transient or measurement actions previously initiated.

Command Syntax

SYSTem:CONFigure <CRD>

Parameters

NORMal IEC

*RST Value

NORMal

Examples

SYST:CONF NORM

Query Syntax

SYSTem:CONFigure?

Returned Parameters

<CRD>

Related Commands

ABORt MEAS:ARR:CURR MEAS:ARR:VOLT CALC:SMO

 

CALC:INT SENS:WIND

179

Page 179
Image 179
Agilent Technologies 6834B, 6814B, 6811B manual SYSTem:CONFigure, Agilent 6812B, 6813B, 6843A Only