Agilent Technologies 6814B, 6834B, 6843A Measurement Subsystem Power, MEASure:POWer? FETCh:POWer?

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 49
Image 49
Measurement Subsystem (Power)

Language Dictionary - 3

Measurement Subsystem (Power)

This subsystem programs the power measurement capability of the ac source. Two measurement commands are available: MEASure and FETCh. MEASure triggers the acquisition of new measurement data before returning a reading. FETCh returns a reading computed from previously acquired data. Individual outputs of a three-phase source are specified by the setting of INSTrument:NSELect.

Subsystem Syntax

MEASure FETCh

 

[:SCALar]

 

:POWer

 

[:DC]?

Returns the dc component of power

:AC

 

[:REAL]?

Returns real power

:APParent?

Returns VA

:REACtive?

Returns VAR

:PFACtor?

Returns power factor

:TOTal?

Returns real 3-phase total power

MEASure:POWer?

FETCh:POWer?

Phase Selectable

These queries return the dc component of the power being sourced at the output terminals in watts.

Query Syntax

MEASure:[SCALar]:POWer[:DC]?

 

FETCh:[SCALar]:POWer[:DC]?

Parameters

None

 

Examples

MEAS:POW?

FETC:POW?

Returned Parameters

<NR3>

 

Related Commands

MEAS:POW:AC?

 

MEASure:POWer:AC?

FETCh:POWer:AC?

Phase Selectable

These queries return the in-phase component of power being sourced at the output terminals in watts.

Query Syntax

MEASure:[SCALar]:POWer:AC[:REAL]?

 

FETCh:[SCALar]:POWer:AC[:REAL]?

Parameters

None

 

Examples

MEAS:POW:AC?

FETC:POW:AC?

Returned Parameters

<NR3>

 

Related Commands

MEAS:POW?

 

49

Page 49
Image 49
Agilent Technologies 6814B Measurement Subsystem Power, MEASure:POWer? FETCh:POWer?, MEASure:POWer:AC? FETCh:POWer:AC?