Agilent Technologies 6813B, 6834B, 6814B, 6843A, 6811B, 6812B manual VOLTage:MODE, VOLTage:OFFSet

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 87
Image 87
VOLTage:MODE

Language Dictionary - 3

VOLTage:MODE

Phase Selectable

This command determines how the ac rms output voltage is controlled during a triggered output transient. The choices are:

FIXed

The voltage is unaffected by a triggered output transient.

STEP

The voltage is programmed to the value set by VOLTage:TRIGgered when a triggered

 

transient occurs.

PULSe

The voltage is changed to the value set by VOLTage:TRIGgered for a duration determined

 

by the pulse commands.

LIST

The voltage is controlled by the voltage list when a triggered transient occurs.

Command Syntax

Parameters

*RST Value

Examples

Query Syntax

Returned Parameters

Related Commands

[SOURce:]VOLTage:MODE <mode> FIXed STEP PULSe LIST

FIXed

 

VOLT:MODE FIX

VOLT:MODE:LIST

[SOURce:]VOLTage:MODE?

<CRD>

VOLT VOLT:TRIG

VOLTage:OFFSet

Agilent 6811B, 6812B, 6813B, Only

This command programs the dc output voltage level of the ac source.

The maximum peak voltage that the ac source can output is 425 V peak. This includes any combination of voltage, voltage offset, and function shape values. Therefore, the maximum value that can be programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the maximum voltage that can be programmed is 300 V rms.

NOTE:

The OUTPut:COUPling must be set to DC to get non-zero dc output.

 

 

 

 

Command Syntax

[SOURce:]VOLTage:OFFSet[:IMMediate] <NRf+>

 

Parameters

–425 to +425 MAXimum MINimum

 

Unit

V (dc voltage)

 

*RST Value

0

 

Examples

VOLT:OFFS 100

 

Query Syntax

[SOURce:]VOLTage:OFFSet[:IMMediate]?

 

Returned Parameters

<NR3>

 

Related Commands

VOLT:OFFS:MODE OUTP:COUP FUNC:SHAP

87

Page 87
Image 87
Agilent Technologies 6813B, 6834B, 6814B, 6843A, 6811B, 6812B manual VOLTage:MODE, VOLTage:OFFSet