Agilent Technologies 6834B, 6814B, 6843A, 6813B manual LIST:COUNt, LIST:CURRent, LIST CURRent POINts?

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 72
Image 72

3 - Language Dictionary

LIST:COUNt

This command sets the number of times that the list is executed before it is completed. The command accepts parameters in the range 1 through 9.9E37, but any number greater than 2E9 is interpreted as infinity. Use INFinity to execute a list indefinitely.

Command Syntax [SOURce:]LIST:COUNt <NRf+> INFinity

Parameters

1 to 9.9E37 MINimum MAXimum INFinity

*RST Value

1

 

Examples

LIST:COUN 3

LIST:COUN INF

Query Syntax

[SOURce:]LIST:COUNt?

Returned Parameters

<NR3>

 

Related Commands

LIST:CURR

LIST:FREQ LIST:TTLT LIST:VOLT

LIST:CURRent

Agilent 6811B, 6812B, 6813B, Only

This command sets the sequence of peak output current list points. The current points are given in the command parameters, which are separated by commas. The order in which the points are entered determines the sequence in which they are output when a list is triggered. Changing list data while a subsystem is in list mode generates an implied ABORt.

Command Syntax

Parameters

Unit

Examples

Query Syntax

Returned Parameters

Related Commands

[SOURce:]LIST:CURRent <NRf+> {,<NRf+>} refer to Specifications Table in User’s Guide A (peak current)

LIST:CURR 2.5,3.0,3.5

LIST:CURR MAX,3.5,2.5,MIN

[SOURce:]LIST:CURRent? <NR3> {,<NR3>}

LIST:CURR:POIN? LIST:COUN LIST:DWEL LIST:STEP

LIST:CURRent:POINts?

Agilent 6811B, 6812B, 6813B, Only

This query returns the number of points specified in LIST:CURRent. Note that it returns only the total number of points, not the point values.

Query Syntax [SOURce:]LIST:CURRent:POINTs?

Returned Parameters <NR1>

Examples LIST:CURR:POIN?

Related Commands LIST:CURR

72

Page 72
Image 72
Agilent Technologies 6834B, 6814B, 6843A, 6813B, 6811B, 6812B manual LIST:COUNt, LIST:CURRent, LIST CURRent POINts?