Agilent Technologies 6811B Source Subsystem Pulse, PULSe:COUNt, PULSe:DCYCle, Subsystem Syntax

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 82
Image 82
Source Subsystem (Pulse)

3 - Language Dictionary

Source Subsystem (Pulse)

This subsystem controls the generation of output pulses. The PULSe:DCYCle, PULSe:HOLD, PULSe:PERiod, and PULSe:WIDTh commands are coupled, which means that the values programmed by any one of these commands can be affected by the settings of the others. Refer to the tables under PULSe:HOLD for an explanation of how these commands affect each other.

Subsystem Syntax

[SOURce:]

 

PULSe

 

:COUNt <n> INFinity

Selects transient pulse count

:DCYCle <n>

Selects pulse duty cycle

:HOLD <parameter>

Selects parameter that is held constant (WIDTh DCYCle)

:PERiod <n>

Selects pulse period when the count is greater than 1

:WIDTh <n>

Selects width of the pulses

PULSe:COUNt

This command sets the number of pulses that are output when a triggered output transient occurs. The command accepts parameters in the range 1 through 9.9E37. If INFinity or MAXimum is sent, the output pulse repeats indefinitely.

Command Syntax

Parameters

*RST Value

Examples

Query Syntax

Returned Parameters

Related Commands

[SOURce:]PULSe:COUNt <Nrf+> INFinity

 

1 to 9.9E37 MINimum MAXimum INFinity

 

1

 

 

PULS:COUN 3

PULS:COUN MIN

PULS:COUN INF

[SOURce:]PULSe:COUNt?

 

<NR3>

 

 

PULS:DCYC

PULS:HOLD PULS:PER

PULS:PER

PULSe:DCYCle

This command sets the duty cycle of the triggered output pulse. The duty cycle units are specified in percent.

Command Syntax

[SOURce:]PULSe:DCYCle <Nrf+>

Parameters

0 to 100 (percent) MINimum MAXimum

*RST Value

50

 

Examples

PULS:DCYC 75

PULS:DCYC MAX

Query Syntax

[SOURce:]PULSe:DCYCle?

Returned Parameters

<NR3>

 

Related Commands

PULS:COUN

PULS:HOLD PULS:PER PULS:WIDT