Agilent Technologies 6813B, 6834B, 6814B, 6843A, 6811B, 6812B manual PHASe:MODE, PHASe:TRIGgered

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 81
Image 81

Language Dictionary - 3

PHASe:MODE

Phase Selectable

This command determines how the output phase is controlled during a triggered output transient. The choices are:

FIXed

The output phase is unaffected by a triggered output transient.

STEP

The output phase is programmed to the value set by PHASe:TRIGgered when a triggered

 

transient occurs.

PULSe

The output phase is changed to the value set by PHASe:TRIGgered for a duration

 

determined by the pulse commands.

LIST

The output phase is controlled by the phase list when a triggered transient occurs.

Command Syntax

Parameters

*RST Value

Examples

Query Syntax

Returned Parameters

Related Commands

[SOURce:]PHASe:MODE <mode> FIXed STEP PULSe LIST

FIXed

 

PHAS:MODE LIST

PHAS:MODE FIX

[SOURce:]PHASe:MODE?

<CRD>

PHAS PHAS:TRIG

PHASe:TRIGgered

Phase Selectable

This command sets the output phase when a triggered step or pulse transient occurs. The phase of the output voltage waveform is expressed relative to an internal reference. The phase angle is programmed in degrees. Positive phase angles are used to program the leading phase, and negative phase angles are used to program the lagging phase.

The PHASe command is not influenced by INSTrument:COUPle ALL. It applies only to the current output phase selected by INSTrument:NSELect.

Command Syntax

Parameters

*RST Value

Examples

Query Syntax

Returned Parameters

Related Commands

[SOURce:]PHASe:TRIGgered <NRf+>

–360 through +360 (degrees) MAXimum MINimum

triggered phase 1

= 0, triggered phase 2 = 240,

triggered phase 3

= 120

PHAS:TRIG 90

PHAS:TRIG MAX

[SOURce:]PHASe:TRIGgered?

<NR3>

PHAS:MODE PHASE

81

Page 81
Image 81
Agilent Technologies 6813B, 6834B, 6814B, 6843A, 6811B, 6812B manual PHASe:MODE, PHASe:TRIGgered