LIST:VOLTage

Language Dictionary - 3

LIST:VOLTage

Phase Selectable

This command specifies the output voltage points in a list. The voltage points are given in the command parameters, which are separated by commas. The order in which the points are entered determines the sequence in which they are output when a list is triggered. Changing list data while a subsystem is in list mode generates an implied ABORt.

The maximum peak voltage that the ac source can output is 425 V peak. This includes any combination of voltage, voltage offset, and function shape values. Therefore, the maximum value that can be programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the maximum voltage that can be programmed is 300 V rms.

NOTE: For Agilent models 6814B, 6834B and 6843A, you cannot program a voltage that produces a higher volt-second on the output than a 300 Vrms sinewave.

Command Syntax

[SOURce:]LIST:VOLTage[:LEVel] <NRf+> {,<NRf+>}

Parameters

For sinewaves: 0 to 300 MAXimum MINimum

Unit

V (rms voltage)

 

 

Examples

LIST:VOLT 115,126,120

LIST:VOLT MAX,120,MIN

Query Syntax

[SOURce:]LIST:VOLTage[:LEVel]?

 

Returned Parameters

<NR3> {,<NR3>}

 

 

Related Commands

LIST:VOLT:POIN?

LIST:COUN

LIST:DWEL LIST:STEP

 

LIST:VOLT:SLEW

LIST:VOLT:OFFS

LIST:VOLTage:POINts?

This query returns the number of points specified in LIST:VOLTage. Note that it returns only the total number of points, not the point values.

Query Syntax

[SOURce:]LIST:VOLTage[:LEVel]:POINTs?

Returned Parameters

<NR1>

Examples

LIST:VOLT:POIN?

Related Commands

LIST:VOLT

LIST:VOLTage:SLEW

Phase Selectable

This command specifies the output voltage slew list points. The slew points are given in the command parameters, which are separated by commas. The order in which the points are entered determines the sequence in which they are output when a list is triggered. Changing list data while a subsystem is in list mode generates an implied ABORt.

Command Syntax

Parameters

Unit

Examples

Query Syntax

Returned Parameters

Related Commands

[SOURce:]LIST:VOLTage:SLEW <NRf+> INF {,<NRf+> INF} 0 to 9.9E37 MAXimum MINimum INFinity

V (volts per second)

LIST:VOLT:SLEW 10,20,1E2

[SOURce:]LIST:VOLTage:SLEW? <NR3> {,<NR3>}

LIST:VOLT:SLEW:POIN? LIST:COUN LIST:DWEL LIST:STEP