FUNCtion:CSINusoid

This command sets the clipping level when a clipped sine output waveform is selected. The clipping characteristics can be specified in two ways:

υThe clipping level is expressed as a percentage of the peak amplitude at which clipping occurs. The range is 0 to 100 percent. These are the default units when the optional THD suffix is not sent.

υThe clipping level is expressed at the percentage of total harmonic distortion in the output voltage. The range is 0 to 43 percent. The optional THD suffix is sent to program in these units.

Command Syntax

[SOURce:]FUNCtion[:SHAPe]:CSINusoid <Nrf> [THD]

Parameters

0 to 100% 0 to 43% THD

*RST Value

100% 0% THD (no clipping)

Examples

FUNC:CSIN 80

FUNC:CSIN 10 THD

Query Syntax

[SOURce:]FUNCtion[:SHAPe]:CSINusoid?

Returned Parameters

<NR3>

 

Related Commands

FUNC FUNC MODE