OUTPut:PON:STATe

This command selects the power-on state of the ac source. The following states can be selected:

RST

RCL0

Sets the power-on state to *RST. Refer to the *RST command as described later in this chapter for more information.

Sets the power-on state to *RCL 0. Refer to the *RCL command as described later in this chapter for more information.

Command Syntax

OUTPut:PON:STATe <state>

Parameters

RST RCL0

Examples

OUTP:PON:STAT RST

Query Syntax

OUTPut:PON:STATe?

Returned Parameters

<CRD>

Related Commands

*RST *RCL

OUTPut:PROTection:CLEar

This command clears the latch that disables the output when an overvoltage (OV), overcurrent (OC), overtemperature (OT), remote inhibit (RI), or power rail fault condition is detected. All conditions that generated the fault must be removed before the latch can be cleared. The output is then restored to the state it was in before the fault condition occurred.

Command Syntax

OUTPut:PROTection:CLEar

Parameters

None

Examples

OUTP:PROT:CLE

Related Commands

OUTP:PROT:DEL *SAV *RCL

OUTPut:PROTection:DELay

This command sets the delay time between the programming of an output change that produces a CL or UNREG status condition and the recording of that condition by the Questionable Status Condition register. The delay prevents momentary changes in status that can occur during programming from being registered as events by the status subsystem. In most cases these temporary conditions are not considered an event, and to record them as such would be a nuisance.

Command Syntax OUTPut:PROTection:DELay <NRf+> Parameters 0 to 100 MAXimum MINimum

Unit S seconds) *RST Value 100 milliseconds

Examples OUTP:PROT:DEL 75E-1

Query Syntax OUTPut:PROTection:DELay?

Returned Parameters <NR3>

Related Commands OUTP:PROT:CLE *SAV *RCL