SYSTem:CONFigure:NOUTputs

Agilent 6834B Only

This command selects the number of output phases for ac sources that have single-phase and three- phase switchable capability. This selection is stored in non-volatile memory and is retained after power-off. The execution of this command disables all outputs, reconfigures the current readback and programming calibration constants, returns all lists and *RCL states to their factory default states, and reboots the ac source. Note that this may require you to reprogram the lists and recall states each time the outputs are switched.

Command Syntax

SYSTem:CONFigure:NOUTputs <NR1>

Parameters

1 or 3

Examples

SYST:CONF:NOUT 1

Query Syntax

SYSTem:CONFigure:NOUTputs?

Returned Parameters

<NR1>

SYSTem:ERRor?

This query returns the next error number followed by its corresponding error message string from the remote programming error queue. The queue is a FIFO (first-in, first-out) buffer that stores errors as they occur. As it is read, each error is removed from the queue. When all errors have been read, the query returns “0, No Error”. If more errors are accumulated than the queue can hold, the last error in the queue is

“-350, Too Many Errors”.

Query Syntax

SYSTem:ERRor?

Parameters

None

Returned Parameters

<NR1>, <SRD>

Examples

SYST:ERR?

SYSTem:VERSion?

This query returns the SCPI version number to which the ac source complies. The value is of the form YYYY.V, where YYYY is the year and V is the revision number for that year.

Query Syntax SYSTem:VERSion?

Parameters None

Examples SYST:VERS?

Returned Parameters <NR2>