Measurement Subsystem (Voltage)

3 - Language Dictionary

Measurement Subsystem (Voltage)

This subsystem programs the voltage measurement capability of the ac source. Two measurement commands are available: MEASure and FETCh. MEASure triggers the acquisition of new measurement data before returning a reading. FETCh returns a reading computed from previously acquired data. Individual outputs of a three-phase source are specified by the setting of INSTrument:NSELect.

Subsystem Syntax

MEASure FETCh

 

[:SCALar]

 

:VOLTage

 

[:DC]?

Returns dc component of the voltage

:AC?

Returns ac rms voltage

:ACDC?

Returns ac+dc rms voltage

:HARMonic

 

[:AMPLitude]? <n>

Returns amplitude of the Nth harmonic of voltage

:PHASe? <n>

Returns phase of the Nth harmonic of voltage

:THD?

Returns % of total harmonic distortion of voltage

MEASure:VOLTage?

FETCh:VOLTage?

Phase Selectable

These queries return the dc component of the output voltage being sourced at the output terminals.

Query Syntax

MEASure:[SCALar]:VOLTage[:DC]?

 

FETCh:[SCALar]:VOLTage[:DC]?

Parameters

None

 

Examples

MEAS:VOLT?

FETC:VOLT?

Returned Parameters

<NR3>

 

Related Commands

MEAS:CURR?

MEAS:VOLT:AC?

MEASure:VOLTage:AC?

FETCh:VOLTage:AC?

Phase Selectable

These queries return the ac rms voltage being sourced at the output terminals.

Query Syntax

MEASure:[SCALar]:VOLTage:AC?

 

FETCh:[SCALar]:VOLTage:AC?

Parameters

None

 

Examples

MEAS:VOLT:AC?

FETC:VOLT:AC?

Returned Parameters