Agilent Technologies 6843A, 6834B STATus QUEStionable ENABle, STATus:QUEStionable:NTRansition

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 98
Image 98
STATus:QUEStionable:ENABle

3 - Language Dictionary

STATus:QUEStionable:ENABle

This command sets or reads the value of the Questionable Enable register. This register is a mask for enabling specific bits from the Questionable Event register to set the questionable summary (QUES) bit of the Status Byte register. This bit (bit 3) is the logical OR of all the Questionable Event register bits that are enabled by the Questionable Status Enable register.

Command Syntax

STATus:QUEStionable:ENABle <NRf+>

Parameters

0 to 32767 MAXimum MINimum

Default Value

0

 

Examples

STAT:QUES:ENAB 32

STAT:QUES:ENAB 1

Query Syntax

STATus:QUEStionable:ENABle?

Returned Parameters

<NR1> (register value)

 

Related Commands

STAT:QUES?

 

STATus:QUEStionable:NTRansition

STATus:QUEStionable:PTRansition

These commands set or read the value of the Questionable NTR (Negative-Transition) and PTR (Positive- Transition) registers. These registers serve as polarity filters between the Questionable Enable and Questionable Event registers to cause the following actions:

υWhen a bit in the Questionable NTR register is set to 1, then a 1-to-0 transition of the corresponding bit in the Questionable Condition register causes that bit in the Questionable Event register to be set.

υWhen a bit of the Questionable PTR register is set to 1, then a 0-to-1 transition of the corresponding bit in the Questionable Condition register causes that bit in the Questionable Event register to be set.

υIf the same bits in both NTR and PTR registers are set to 1, then any transition of that bit at the Questionable Condition register sets the corresponding bit in the Questionable Event register.

υIf the same bits in both NTR and PTR registers are set to 0, then no transition of that bit at the Questionable Condition register can set the corresponding bit in the Questionable Event register.

NOTE: Setting a bit in the PTR or NTR filter can of itself generate positive or negative events in the corresponding Questionable Event register.

Command Syntax

Parameters

Default Value

Examples

Query Syntax

Returned Parameters Related Commands

STATus:QUEStionable:NTRansition <NRf+> STATus:QUEStionable:PTRansition <NRf+> 0 to 32767 MAXimum MINimum

0

 

STAT:QUES:NTR 32

STAT:QUES:PTR 1

STATus:QUEStionable:NTRansition?

STATus:QUEStionable:PTRansition? <NR1> (register value)