Agilent Technologies 6811B, 6834B, 6814B, 6843A Status Subsystem, STATus:PRESet, Subsystem Syntax

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 94
Image 94
Status Subsystem

3 - Language Dictionary

Status Subsystem

This subsystem programs the ac source status registers. The ac source has four groups of status registers; Operation, Questionable, Questionable Instrument ISummary and Standard Event. The Standard Event group is programmed with Common commands. The Operation, Questionable, and Instrument ISummary status groups each consist of the following five registers:

Condition Enable Event NTR Filter PTR Filter.

Refer to Chapter 4 under “Programming the Status Registers” for more information.

Subsystem Syntax

STATus

 

:PRESet

Presets all enable and transition registers to power-on

:OPERation

 

[:EVENt]?

Returns the value of the event register

:CONDition?

Returns the value of the condition register

:ENABle <n>

Enables specific bits in the Event register

:NTRansition<n>

Sets the Negative transition filter

:PTRansition<n>

Sets the Positive transition filter

:QUEStionable

 

[:EVENt]?

Returns the value of the event register

:CONDition?

Returns the value of the condition register

:ENABle <n>

Enables specific bits in the Event register

:NTRansition<n>

Sets the Negative transition filter

:PTRansition<n>

Sets the Positive transition filter

:INSTrument

 

:ISUMmary

 

[:EVENt]?

Returns the selected phase's event register value

:CONDition?

Returns the selected phase's condition register value

:ENABle <n>

Enables specific bits in the selected phase's Event register

:NTRansition<n>

Sets the selected phase's Negative transition filter

:PTRansition<n>

Sets the selected Phase's Positive transition filter

STATus:PRESet

This command sets the Enable, PTR, and NTR registers of the status groups to their power-on values. These values are:

Enable Registers: all bits set to 0 (OFF)

PTR Registers: all defined bits set to 1 (ON)

NTR Registers: all bits set to 0 (OFF)

Command Syntax STATus:PRESet

Parameters None

Examples STAT:PRES

94

Page 94
Image 94
Agilent Technologies 6811B, 6834B, 6814B, 6843A, 6813B, 6812B manual Status Subsystem, STATus:PRESet, Subsystem Syntax