Agilent Technologies 6843A, 6834B, 6814B VOLTage SENSe SOURce VOLTage ALC SOURce, VOLTage:SLEW

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 92
Image 92

3 - Language Dictionary

VOLTage:SENSe:SOURce

VOLTage:ALC:SOURce

These commands select the source from which the output voltage is sensed. The commands are interchangeable; they both perform the same function. The following voltage sense sources can be selected:

INTernal

EXTernal

This senses the voltage at the output of the power amplifier on the inboard side of the output disconnect relay.

This senses the output voltage at the rear panel voltage sense terminals, which allows remote voltage sensing at the load.

Command Syntax

[SOURce:]VOLTage:SENSe:SOURce <source>

 

[SOURce:]VOLTage:ALC:SOURce <source>

Parameters

INTernal EXTernal

 

*RST Value

INTernal

 

Examples

VOLT:SENS:SOUR INT

VOLT:ALC:SOUR EXT

Query Syntax

[SOURce:]VOLTage:SENSe:SOURce?

 

[SOURce:]VOLTage:ALC:SOURce?

Returned Parameters

<CRD>

 

Related Commands

VOLT:SENS:DET

 

VOLTage:SLEW

Phase Selectable

This command sets the slew rate for all programmed changes in the ac rms output voltage level of the ac source. A parameter of MAXimum or INFinity sets the slew to its maximum possible rate. The SCPI representation for INFinity is 9.9E37.

Command Syntax

[SOURce:]VOLTage:SLEW[:IMMediate] <NRf+> INFinity

Parameters

0 to 9.9E37 MAXimum MINimum INFinity

Unit

V (volts per second)

 

*RST Value

INFinity

 

Examples

VOLT:SLEW 50

VOLT:SLEW INF

Query Syntax

[SOURce:]VOLTage:SLEW[:IMMediate]?

Returned Parameters

<NR3>

 

Related Commands

VOLT:SLEW:MODE

VOLT:SLEW:TRIG