Agilent Technologies 6834B, 6814B Sense Subsystem, SENSe:CURRent:ACDC:RANGe, Subsystem Syntax

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 60
Image 60
Sense Subsystem

3 - Language Dictionary

Sense Subsystem

This subsystem controls the measurement current range, the data acquire sequence, and the harmonic measurement window of the ac source.

Subsystem Syntax

SENSe

 

:CURRent

 

:ACDC

 

:RANGe

 

[:UPPer]<n>

Sets measurement current range

:SWEep

 

:OFFSet

 

:POINts <n>

Define trigger points relative to the start of the digitizer data record

:TINTerval <n>

Sets the digitizer sample spacing

:WINDow

 

[:TYPE] <type>

Sets measurement window type (KBESsel RECTangular)

SENSe:CURRent:ACDC:RANGe

Agilent 6811B, 6812B, 6813B, Only

This command sets the current measurement range. There are two current measurement ranges:

Agilent 6811B

High Range: 0 through 28.5671 Arms ( 40.4 Apeak through + 40.4 Apeak)

Low Range: 0 through 2.85671 Arms ( 4.04 Apeak through + 4.04 Apeak)

Agilent 6812B, Agilent 6813B

High Range: 0 through 57.1342 Arms ( 80.8 Apeak through + 80.8 Apeak)

Low Range: 0 through 5.71342 Arms ( 8.08 Apeak through + 8.08 Apeak)

The high range covers the maximum current measurement capability of the instrument. The low range increases the low current measurement sensitivity by a factor of 10 for greater accuracy and resolution.

The value that you program with SENS:CURR:ACDC:RANG must be the maximum rms current that you expect to measure. Based on this value, the instrument will select the range that gives the best resolution in measuring a sinusoidal waveform of that rms value. The crossover value of the two ranges is 5.71342 Arms. (2.85671 Arms for Agilent 6811B)

Command Syntax Parameters

Unit

*RST Value

Examples

Query Syntax

Returned Parameters

Related Commands

SENSe:CURRent:ACDC:RANGe[:UPPer] <NRf+>

0 through 57.1342 MINimum MAXimum (all except Agilent 6811B) 0 through 28.5671 MINimum MAXimum (Agilent 6811B only)

A(rms amperes) MAX (high range)

SENS:CURR:ACDC:RANGE MIN

SENSe:CURRent:ACDC:RANGe?

<NR3>