Measurement Subsystem (Current)

3 - Language Dictionary

Measurement Subsystem (Current)

This subsystem programs the current measurement capability of the ac source. Two measurement commands are available: MEASure and FETCh. MEASure triggers the acquisition of new measurement data before returning a reading. FETCh returns a reading computed from previously acquired data.

Individual outputs of a three-phase source are specified by the setting of INSTrument:NSELect.

Subsystem Syntax

MEASure FETCh

 

[:SCALar]

 

:CURRent

 

[:DC]?

Returns dc component of the current

:AC?

Returns ac rms current

:ACDC?

Returns ac+dc rms current

:AMPLitude

 

:MAX?

Returns peak current

:CREStfactor?

Returns current crestfactor

:HARMonic

 

[:AMPLitude]? <n>

Returns amplitude of the Nth harmonic of current

:PHASe? <n>

Returns phase of the Nth harmonic of current

:THD?

Returns % of total harmonic distortion of current

:NEUTral

 

[:DC]?

Returns neutral dc current (3-phase only)

:AC?

Returns neutral ac rms current (3-phase only)

:ACDC?

Returns neutral ac+dc rms current (3-phase only)

:HARMonic

 

[:AMPLitude]? <n> Returns neutral current harmonic amplitude (3-phase only)

:PHASe? <n>

Returns neutral current harmonic phase (3-phase only)

MEASure:CURRent?

FETCh:CURRent?

Phase Selectable

These queries return the dc component of the output current being sourced at the output terminals.

Query Syntax

MEASure:[SCALar]:CURRent[:DC]?

 

FETCh:[SCALar]:CURRent[:DC]?

Parameters

None

 

Examples

MEAS:CURR?

FETC:CURR?

Returned Parameters

<NR3>

 

Related Commands

MEAS:VOLT?

MEAS:CURR:AC?