Agilent Technologies 6813B, 6834B, 6814B, 6843A, 6811B CURRent:PEAK:MODE, Curr:Peak:Mode Fix

Models: 6811B 6813B 6834B 6843A 6814B

1 187
Download 187 pages 38.86 Kb
Page 63
Image 63

Language Dictionary - 3

CURRent:PEAK

Agilent 6811B, 6812B, 6813B, Only

This command sets the output limit of the absolute value of peak instantaneous current.

Command Syntax

[SOURce:]CURRent:PEAK[:IMMediate] <NRf+>

Parameters

refer to Specifications Table in User’s Guide

Unit

A (peak amperes)

*RST Value

13

(Agilent 6811B/6812B)

 

26

(Agilent 6813B)

Examples

CURR:PEAK:IMM 15

Query Syntax

[SOURce:]CURRent:PEAK[:IMMediate]?

Returned Parameters

<NR3>

Related Commands

CURR:PEAK:MODE CURR:PEAK:TRIG

CURRent:PEAK:MODE

Agilent 6811B, 6812B, 6813B, Only

This command determines how the peak current limit is controlled during a triggered output transient. The choices are:

FIXed

The peak current limit is unaffected by a triggered output transient.

STEP

The peak current limit is programmed to the value set by CURRent:PEAK:TRIGgered

 

when a triggered transient occurs.

PULSe

The peak current limit is changed to the value set by CURRent:PEAK:TRIGgered for a

 

duration determined by the pulse commands.

LIST

The peak current limit is controlled by the peak current list when a triggered transient

 

occurs.

Command Syntax

[SOURce:]CURRent:PEAK:MODE <mode>

Parameters

FIXed STEP PULSe LIST

*RST Value

FIXed

Examples

CURR:PEAK:MODE FIX

Query Syntax

[SOURce:]CURRent:PEAK:MODE?

Returned Parameters

<CRD>

Related Commands

CURR:PEAK CURR:PEAK:TRIG