Electrical Specifications

32579B

Table 9-24. Sub-ISA Timing Parameters (Continued)

 

 

Bus

 

 

 

 

 

 

 

Width

 

Min

Max

 

 

Symbol

Parameter

(Bits)

Type

(ns)

(ns)

Figure

Comments

 

 

 

 

 

 

 

 

tRDYA2

IOCHRDY valid after IOR#/MEMR#/

8

M, I/O

 

366

9-20

 

 

RD#/DOCR#/IOW#/MEMW#/WR#/

 

 

 

 

9-21

 

 

DOCW# FE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tIOCSA

IOCS[1:0]#/DOCS#/ROMCS# driven

8, 16

M, I/O

 

34

9-20

 

 

active from A[23:0] valid

 

 

 

 

9-21

 

 

 

 

 

 

 

 

 

tIOCSH

IOCS[1:0]#/DOCS#/ROMCS# valid

8, 16

M, I/O

0

 

9-20

 

 

hold after A[23:0] invalid

 

 

 

 

9-21

 

 

 

 

 

 

 

 

 

tAR1

A[23:0]/BHE# valid before

16

M

34

 

9-20

 

 

MEMR#/DOCR# active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tAR2

A[23:0]/BHE# valid before IOR#

16

I/O

100

 

9-20

 

 

active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tAR3

A[23:0]/BHE# valid before

8

M, I/O

100

 

9-20

 

 

MEMR#/DOCR#/IOR# active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tRA

A[23:0]/BHE# valid hold after

8, 16

M, I/O

25

 

9-20

 

 

MEMR#/DOCR#/IOR# inactive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tRVDS

Read data D[15:0] valid setup before

8, 16

M, I/O

24

 

9-20

 

 

MEMR#/DOCR#/IOR# inactive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tRDH

Read data D[15:0] valid hold after

8, 16

M, I/O

0

 

9-20

 

 

MEMR#/DOCR#/IOR# inactive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tHZ

Read data floating after

8, 16

M, I/O

 

41

9-20

 

 

MEMR#/DOCR#/IOR# inactive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tAW1

A[23:0]/BHE# valid before

16

M

34

 

9-21

 

 

MEMW#/DOCW# active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tAW2

A[23:0]/BHE# valid before IOW#

16

I/O

100

 

9-21

 

 

active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tAW3

A[23:0]/BHE# valid before

8

M, I/O

100

 

9-21

 

 

MEMW#/DOCW#/IOW# active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tWA

A[23:0]/BHE# valid hold after

8, 16

M, I/O

25

 

9-21

 

 

MEMW#/DOCW#/IOW# invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tDV1

Write data D[15:0] valid after

8, 16

M

40

 

9-21

 

 

MEMW#/DOCW# active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tDV2

Write data D[15:0] valid after IOW#

8

I/O

40

 

9-21

 

 

active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tDV3

Write data D[15:0] valid after IOW#

16

I/O

-23

 

9-21

 

 

active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tWTR

TRDE# inactive after

8, 16

M, I/O

20

 

9-21

 

 

MEMW#/DOCW#/IOW# inactive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tDH

Write data D[15:0] after

8, 16

M, I/O

45

 

9-21

 

 

MEMW#/DOCW#/IOW# inactive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tDF

Write data D[15:0] goes TRI-STATE

8, 16

M, I/O

 

105

9-21

 

 

after MEMW#/DOCW#/IOW# inactive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tWDAR

Write data D[15:0] after read

8, 16

M, I/O

41

 

9-20

 

 

MEMR#/DOCR#/IOR#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMD Geode™ SC1200/SC1201 Processor Data Book

395

Page 395
Image 395
AMD SC1201, SC1200 manual Bus Width Min Max Symbol Parameter Bits Type Comments, Memr#/Docr#/Ior#