32579B

SuperI/O Module

5.5.2.6Power Supply

The device is supplied from two supply voltages, as shown in Figure 5-8:

System standby power supply voltage, VSB

Backup voltage, from low capacity Lithium battery

A standby voltage, VSB, from the external AC/DC power supply powers the RTC under normal conditions.

Figure 5-9represents a typical battery configuration. No external diode is required to meet the UL standard, due to the internal switch and internal serial resistor RUL.

 

 

External AC Power

ACPI Controller

 

Power

 

 

Supply

VDIGITAL Sense

VDIGITAL

VDIGITAL

 

 

The RTC is supplied from one of two power supplies, VSB or VBAT, according to their levels. An internal voltage com- parator delivers the control signals to a pair of switches. Battery backup voltage VBAT maintains the correct time and saves the CMOS memory when the VSB voltage is absent, due to power failure or disconnection of the external AC/DC input power supply or VSB main battery.

To assure that the module uses power from VSB and not from VBAT, the VSB voltage should be maintained above its minimum, as detailed in Section 9.0 "Electrical Specifica- tions" on page 365.

The actual voltage point where the module switches from VBAT to VSB is lower than the minimum workable battery voltage, but high enough to guarantee the correct function- ality of the oscillator and the CMOS RAM.

Figure 5-10shows typical battery current consumption dur- ing battery-backed operation, and Figure 5-11during nor- mal operation.

 

PC0

 

ONCTL#

ONCTL#

 

 

VSB

 

RTC

VSB

VSB

 

 

VSB

 

 

 

 

 

VBAT

VBAT

VBAT

Backup

 

 

 

 

 

 

Battery

Figure 5-8. Power Supply Connections

IBAT (μA)

10.0

7.5

5.0

2.5

2.4 3.0 3.6

VBAT (V)

 

VSB

 

VSB

 

RTC

CF

 

 

0.1 μF

VPP

VSBL

CF

VSBL

 

VREF

0.1 μF

 

VBAT

 

BT1

 

 

 

 

RUL

CF

 

 

 

0.1 μF

 

Note: Place a 0.1 μF capacitor on each VSB, VSBL power supply pin as close as possible to the pin, and also on VBAT.

Figure 5-9. Typical Battery Configuration

Figure 5-10. Typical Battery Current: Battery

Backed Power Mode @ TC = 25°C

IBAT (μA)

0.75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.25

 

 

 

 

 

 

 

 

VSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0 3.3 3.6

 

 

 

(V)

 

 

 

 

Note: Battery voltage in this test is 3.0V.

Figure 5-11. Typical Battery Current: Normal

Operation Mode

108

AMD Geode™ SC1200/SC1201 Processor Data Book

Page 108
Image 108
AMD SC1200, SC1201 manual Power Supply