6. PARAMETER DESCRIPTION

(12) Item N (Menu N): Loop Test Setting items

Menu N contains items that are relevant to the execution of loop testing.

 

Name

 

Data range

 

Position

Default value

 

 

 

 

 

Units

 

Item

Display unit

R/W

Display unit

of decimal

Description

(*): Indicated item

 

(BRAIN)

 

/BRAIN

 

point

 

 

N00

Test

 

 

 

 

 

 

 

(TEST)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N10

Test Mode

W

Normal

 

 

Normal

Selects whether mode will be set

 

(TEST MODE)

 

Test

 

 

 

to “Normal” or “Test”.

N11

Test Output Value

W

-10 to 110

%

0

0%

Sets the test output value.

 

(TEST OUT VAL)

 

 

 

 

 

 

N20

Test SO1

W

Open(Off)

 

 

Open(Off)

Selects the test condition for

 

(TEST SO1)

 

Closed(On)

 

 

 

SO1 terminal.

N21

Test SO2

W

Open(Off)

 

 

Open(Off)

Selects the test condition for

 

(TEST SO2)

 

Closed(On)

 

 

 

SO2 terminal.

 

 

 

 

 

 

 

 

N22

Test Alarm Out

W

Open(Off)

 

 

Closed(On)

Selects the test condition for

 

(TEST ALM OUT)

 

Closed(On)

 

 

 

alarm output terminal.

N23

Test SI1

R

Open

 

 

 

Displays the test condition for

 

(TEST SI1)

 

Short

 

 

 

SI1 terminal.

 

 

 

 

 

 

 

 

N24

Test SI2

R

Open

 

 

 

Displays the test condition for

 

(TEST SI2)

 

Short

 

 

 

SI2 terminal.

 

 

 

 

 

 

 

 

N60

R

Good

 

 

 

See “6.5 Alarm Functions”.

 

(SELF CHECK)

 

Error

 

 

 

 

T0613.EPS

(13) Item P (Menu P): Parameter Protection items

Menu P contains items that are relevant to write protection and passwords.

 

Name

 

Data range

 

Position

Default value

 

Item

 

 

 

Units

Description

Display unit

R/W

Display unit

of decimal

(*): Indicated item

 

(BRAIN)

 

/BRAIN

 

point

 

 

P00

Protect

 

 

 

 

 

 

 

(PROTECT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P10

Key Code

W

0 to 9999

 

 

0

Parameter of the display restriction

 

(KEY CODE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P20

Write Protect

R

No

 

 

No

Displays whether or not overwriting

 

(W PROTECT)

 

Yes

 

 

 

of parameter data is prohibited.

P21

Enable Wrt Passwd

W

ASCII 8 characters

 

 

 

Sets the correct password so that

 

(ENABLE WRITE)

 

 

 

 

 

write protection function will be

 

 

 

 

 

 

 

released.

 

 

 

 

 

 

 

 

P22

New Password

W

ASCII 8 characters

 

 

 

Sets the password for write protection

 

(NEW PASSWORD)

 

 

 

 

 

funcion

P23

Software Seal

R

Break

 

 

 

Displays whether or not a Joker

 

(SOFT SEAL)

 

Keep

 

 

 

password was used (Break).

 

 

 

 

 

 

 

 

P60

R

Good

 

 

 

See “6.5 Alarm Functions”.

 

(SELF CHECK)

 

Error

 

 

 

 

 

 

 

 

 

 

 

 

T0613-1.EPS