6. PARAMETER DESCRIPTION

(3) Item C (Menu C): Basic Setting items

Menu C principally contains the basic setting items for the flowtube.

 

Name

 

Data range

 

Position

Default value

 

 

 

 

 

Units

 

Item

Display unit

R/W

Display unit

of decimal

Description

(*): Indicated item

 

 

(BRAIN)

 

/BRAIN

 

point

 

 

C00

Basic Setup

 

 

 

 

 

 

 

(BASIC SETUP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C10

Tag No

W

ASCII 16 characters

 

 

 

Sets Tag number up to 16

 

(TAG NO)

 

 

 

 

 

characters.

 

 

 

 

 

 

 

 

C11

Flow Damping

W

0.1 to 200.0

s

1

3.0 s

Sets damping time. Linked with

 

(FLOW DAMPING)

 

 

 

 

 

B20.

C20

Measure Mode

W

Standard DF

 

 

Standard DF

Selects measurement mode for

 

(MEASURE MODE)

 

Enhanced DF

 

 

 

dual frequency excitation

C21

Low MF

W

0.0100 to 3.0000

 

4

1.0000 (*)

Sets low-frequency meter factor for

 

(LOW MF)

 

 

 

 

 

standard dual frequency excitation

C22

High MF

W

0.0100 to 3.0000

 

4

1.0000 (*)

Sets high-frequency meter factor for

 

(HIGH MF)

 

 

 

 

 

standard dual frequency excitation

C23

Low MF(EDF)

W

0.0000 to 3.0000

 

4

1.0000 (*)

Sets low-frequency meter factor for

 

(LOW MF(EDF))

 

 

 

 

 

enhanced dual frequency excitation

C24

High MF(EDF)

W

0.0000 to 3.0000

 

4

1.0000 (*)

Sets high-frequency meter factor for

 

(HIGH MF(EDF))

 

 

 

 

 

enhanced dual frequency excitation

C30

Select Flow Tube

W

ADMAG AXF

 

 

ADMAG AXF

Selects the flowtube's model

 

(FLOW TUBE)

 

ADMAG

 

 

 

name.

 

 

 

ADMAG AE

 

 

 

 

 

 

 

ADMAG SE

 

 

 

 

 

 

 

YEWMAG

 

 

 

 

 

 

 

Calibrator

 

 

 

 

 

 

 

Other

 

 

 

 

C31

Nominal Size Unit

W

mm

 

 

mm

Selects the nominal size units for

 

(SIZE UNIT)

 

inch

 

 

inch

the flowtube.

C32

Nominal Size

W

0.99 to 3000.1

mm

0 to 2

100 (*)

Sets flowtube nominal size in

 

(NOMINAL SIZE)

 

0.01 to 120.1

inch

 

 

selected unit at C31.

C40

Base Flow Unit

W

Ml(Megaliter)

 

 

m (*)

Selects flow units for the flow

 

(FLOW UNIT)

 

m3

 

 

 

rate span. Linked with B21.

 

 

 

kl(Kiloliter)

 

 

 

 

 

 

 

l(Liter)

 

 

 

 

 

 

 

cm3

 

 

 

 

 

 

 

m

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

kg

 

 

 

 

 

 

 

g

 

 

 

 

 

 

 

kcf

 

 

 

 

 

 

 

cf

 

 

 

 

 

 

 

mcf

 

 

 

 

 

 

 

Mgal (US)

 

 

 

 

 

 

 

kgal (US)

 

 

 

 

 

 

 

gal (US)

 

 

 

 

 

 

 

mgal (US)

 

 

 

 

 

 

 

kbbl (US Oil)

 

 

 

 

 

 

 

bbl (US Oil)

 

 

 

 

 

 

 

mbbl (US Oil)

 

 

 

 

 

 

 

ubbl (US Oil)

 

 

 

 

 

 

 

kbbl (US Beer)

 

 

 

 

 

 

 

bbl (US Beer)

 

 

 

 

 

 

 

mbbl (US Beer)

 

 

 

 

 

 

 

ubbl (US Beer)

 

 

 

 

 

 

 

ft

 

 

 

 

 

 

 

klb (US)

 

 

 

 

 

 

 

lb (US)

 

 

 

 

C41

Base Time Unit

W

/d

 

 

/s (*)

Selects time units for the flow

 

(TIME UNIT)

 

/h

 

 

 

rate span. Linked with B22.

 

 

 

/min

 

 

 

 

 

 

 

/s

 

 

 

 

 

 

 

 

 

 

 

 

C42

Flow Span

W

0.0001 to 32000

C40/C41

0 to 4

1 m/s (*)

Sets flow rate span (with units

 

(FLOW SPAN)

 

 

(B21

 

 

from C40 and C41). Linked with

 

 

 

 

/B22)

 

 

B23.

 

 

 

 

 

 

 

 

C43

Flow Decimal Pnt

W

Auto

 

 

Auto (*)

Selects decimal point position for

 

(FLOW DECIMAL)

 

0

 

 

 

the display unit's instantaneous

 

 

 

1

 

 

 

flow rate. Linked with B24.

 

 

 

2

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

T0604-1.EPS

6-4

IM 01E20C01-01E

Page 32