Reassign an RS232 connector function

Change length of RETURN Delay

Change Baud Rate

1 At Action = , enter 1.

2At Data = , enter the function you want to assign to the Target connector from the following list:

0 - None (disconnect function)

1 - Admin. (Target 1 or 4 only)

2 - SMDR (Target 2 or 3 only)

3 - Tape (Target 3 only)

4 - Reserved

See footnote* on previous page for default function.

Note Unless you’re already administering the Target connector for which you wish to change the RETURN delay, you must first select a Target connector (by entering t or T and then entering the appropriate number at the “RS232=” prompt).

1 At Action = , enter 2.

2 At Data = , enter a number from 0 through 2. The default is 0.

Note Unless you are already administering the Target connector for which you wish to change the Baud Rate, you must first select a Target connector (by entering t or T and then entering the appropriate number at the “RS232=” prompt).

1 At Action = , enter 3.

2 At Data = , enter 300, 1200, 4800, or 9600.

See footnote* on previous page for the default data.

15-2Administering RS232 Parameters

Page 117
Image 117
AT&T R1V2 manual At Data = , enter 300, 1200, 4800, or