TABLE 16-16 Port Options

PORTS, Station/Trunk/Special Port Circuit Board Options

FOR QUALIFIED SYSTEMS TECHNICIANS ONLY*

(See Table 16-17,“Applicable Options”)

ACTION

DESCRIPTION

DATA

32

Set CO disconnect time (in 20 msec increments)

[0-2540 msec; 500]

33

Set end-to-end signaling tone timing

[0-2540 msec; 60]

 

(in 20 msec increments)

[0-2540 msec; 60]

34

Set end-to-end signaling pause timing

 

(in 20 msec increments)

[1 / 0]

35

Set hybrid balance. Data is balance type: 1=Resistor;

 

0=Resistor/Capacitor. Trunk ports default to 0;

 

 

station ports default to 1.

[1 / 0]

36

Set gain; 1 (Gain=3dB) or 0 (Gain=0dB)

37

Set E&M signaling type. Data is signaling type 0

[0 - 2]

 

(Type 1 compatible), 1 (Type V), or 2 (Type I).

[0-5100 msec; 300]

38

Set answer supervision delay timing

* WARNING:

The default values in Tables 16-16 and 16-17must not be changed without

 

the support and guidance of Tier III staff.

Command Reference 16-19

Page 135
Image 135
AT&T R1V2 manual PORTS, Station/Trunk/Special Port Circuit Board Options, See -17,Applicable Options