Class-of-Service Options

Follow the procedures below to assign class-of-service options to this trunk.

Pooled Facility Access

Group: Is this trunk in a pooled facility access group?

1 At Action = , enter 4.

2 At Data = , if the trunk is in a pooled facility access group, enter the facility access code (FAC). Enter 0 if the trunk is not in any group. The defaults are as follows:

100 for Loop Start trunks

101 for Ground Start trunks

102 for Tie trunks

Dial Access

1 At Action = , enter

5.

 

 

2 At Data = , enter 1 if

you want

to allow dial access, enter

 

0 if you do not. The default is

1@.

DGC Group: To assign this trunk to a DGC group

Note This item is not administerable for trunk types 1003-

1008.

1 At Action = , enter 6.

2 At Data = , enter the DGC group number (l-32, or 0 for none). The default is 0.

Night Service: To choose either Directed or Trunk- Answer-from-Any-Station (TAAS) Night Service for this trunk

To receive either form of night service, this trunk’s class of service must include night service (that is, for Action=3, Data must be between 8 and 15). Also, a NIGHT button must be assigned to the attendant console.

For Directed Night Service, at least one station must be assigned to receive night service calls from this trunk (see Administering Voice Stations).

For TAAS Night Service, an external alert must be assigned for night service use.

(continued)

@ Strongly recommended this value be used

Administering Trunks 5-5