Chapter 2: Overview

2. Overview

2.1 Introduction

Use the 8-Port 10/100BASE-TX Hardened Ethernet Extender Switch in harsh environments where space is limited.

2.2 Features

The Hardened Ethernet Extender Switch:

Meets NEMA TS1/TS2 environmental requirements, including temperature, shock, and vibration for traffic control equipment.

Meets EN61000-6-2 and EN61000-6-4 EMC generic standard immunity for an industrial environment.

Manageable via SNMP, Web browser, Telnet, and RS-232 console port.

RS-232 console supports command-line interface.

Ethernet Extender ports are asymmetrical or symmetrical on the VDSL, full- duplex 59-Mbps downstream/31-Mbps upstream asymmetrical, or full-duplex 50-Mbps symmetrical communications link over an existing copper telephone line.

Operates transparently to higher-layer protocols such as TCP/IP.

Two DIP switches configure local (LOC) and remote (REM).

Supports 802.3/802.3u/802.3x autonegotiating, 10-/100-Mbps, full-/half- duplex, auto MDI-MDI-X Ethernet ports.

Supports 8192 MAC addresses.

Provides 2 MB of memory buffer.

Relay output alarms indicate power and port link failure.

Includes redundant 12–48-VDC power terminal block power inputs and 12-VDC jack with a 100–240-VAC external power supply.

Operating voltage and maximum current consumption are: 0.92 A @12 VDC, 0.46 A @ 24 VDC, 0.23 A @ 48 VDC. Maximum power consumption is 11 W.

Operating temperature range is -40 to +167° F (-40 to +75° C).

Supports DIN rail and panel mounting installation.