Chapter 3: Installation
Ethernet Extender Switch.
| 1 |
|
4 | 3 | 5 |
| ||
| 2 | |
|
|
Figure 2-3. Power connectors on the switch.
3.3.3 Alarms for Power Failure
Step 1: There are two pins on the terminal block used to detect a power failure. The output is normally closed when the power source is active. Use this as a dry- contact application to send a signal that detects a power failure.
Table 3-1. Power input assignment.
Number | Input | Polarity | Voltage | Connector | |
|
|
|
|
| |
1 | Power 3 |
| 12 VDC | DC jack | |
|
|
|
|
| |
2 | Power 2 | + |
| ||
|
|
| |||
- | Power Ground |
| |||
|
|
| |||
|
|
|
|
| |
3 | Power 1 | + | Terminal block | ||
|
| ||||
- | Power Ground | ||||
|
|
| |||
|
|
|
|
| |
4 |
|
| Earth Ground |
| |
|
|
|
|
| |
5 | Relay output rating |
|
| 1 A @24 VDC | |
|
|
|
|
|
Page 28 |
| LB308A |
|
|