Carrier 30XW150-400 specifications To change the Time and Date, press the Main Menu

Models: 30XW150-400

1 148
Download 148 pages 52.93 Kb
Page 7
Image 7
To change the Time and Date, press the  Main Menu

Setting the Time and Date — The ComfortLink™ control has a time and date function. This can be useful for diagnostics to determine when alarms occur. The control is factory config- ured for the proper date and is set for the Eastern Time Zone. The date and time zone must be checked and corrected if nec- essary, to allow the machine to function on an internal time schedule and to display a proper time and date stamp for alarms. The time and date is displayed on the Group Display Screen.

To change the Time and Date, press the Manual background Main Menu

button. Select Manual background Time. On the display, a day and date box with a time box will be shown. To change the day and date, press the day and date box. A calendar will be displayed. If the correct month is displayed, touch the correct date. If the wrong month is displayed, use the Manual background or Manual background to change to the correct month and select the correct date. The date will highlighted.

Press Manual background to accept the change. The previous screen will be displayed with the corrected day and date shown. To correct the time, use the Manual background or Manual background on the left to change the hour. Use the Manual background or Manual background on the left to change the minutes. Continuously touching the Manual background or Manual background will sequence the numbers. The time is shown in a 24-hour format. To accept the changes, press the Manual background or Manual background buttons. A “Save” dialog box is displayed with the

words, “Do you wish to save changes?” Press Manual background to accept the changes.

Group Display Screens — The Touch Pilot™ display sup- ports up to eight Group Display screens. Group Display screens show status information along the top of the screens and 9 buttons that display 9 point names and point values that are chosen by the user. All Group Display screen points are user configurable. The bottom line of the screen contains navi- gation buttons that can be used to move between the Group Display screens.

Pressing a point button will show that point’s Point Data dialog box. See Fig. 2 and 3. This box contains buttons that remove the point from the group display and apply or remove a force (point override). When touching any button in the display screen, the button will be outlined to acknowledge input. There may be a delay in response to input, but if the button is out- lined, do NOT press any other button until the previous input has been processed.

If there is a communication failure with the MBB (Main Base Board), all point buttons will be displayed in inverse vid- eo and the message Communication Failure will be displayed in the top left line of the screen.

Default Group Designation — The default group is the first of the 8 Group Display screens. This is the default screen of the display. Information on this screen as well as the other 7 screens can be user-modified to meet the needs of the site.

To Add A Point To A Group Display — From the Main Menu, press the desired menu button (Status, Setpoint, Service, Maint, or Config) and, if necessary, the sub-menu button to access the point to be added. Press the point button to show the source point’s Point Data dialog box. See Fig. 3. From the Point Data dialog box, press the ADD button. The display will show the last Group Display accessed. Use the navigation but- tons to access the destination Group Display. Press an existing point button or a blank button to update the highlighted button with the source point’s name. Press to add the highlighted point to the group and return to the table display.

To Remove A Point From A Group Display — From the Point Data Dialog box, press the REMOVE button and follow the prompts. The display will return to the Group Display screen from which the point was removed, and the button correspond- ing to the deleted point will be blank and disabled.

NAVIGATOR™ DISPLAY MODULE — The Navigator dis- play module provides a mobile user interface to the ComfortLink control system. The display has up and down ar- row keys, an ENTER key, and an ESCAPE key. These keys are used to navigate through the different levels of the display structure. Press the ESCAPE key until ‘Select a Menu Item’ is displayed. Use the up and down arrow keys to move through the top 11 mode levels indicated by LEDs on the left side of the display. See Fig. 7. See Table 2 and Appendix B for more de- tails about the display menu structure.

Once within a mode or sub-mode, a “>” indicates the currently selected item on the display screen. Pressing the ENTER and ESCAPE keys simultaneously will put the Navigator module into expanded text mode where the full meaning of all sub-modes, items, and their values can be dis- played. Pressing the ENTER and ESCAPE keys when the display says ‘Select Menu Item’ (Mode LED level) will return the Navigator module to its default menu of rotating display items (those items in Run StatusVIEW). In addition, the password will be disabled, requiring that it be entered again be- fore changes can be made to password protected items. Press the ESCAPE key to exit out of the expanded text mode.

When a specific item is located, the item name appears on the left of the display, the value will appear near the middle of the display and the units (if any) will appear on the far right of the display. Press the ENTER key at a changeable item and the value will begin to flash. Use the up and down arrow keys to change the value, and confirm the value by pressing the ENTER key.

Changing item values or testing outputs is accomplished in the same manner. Locate and display the desired item. Press ENTER so that the item value flashes. Use the arrow keys to change the value or state and press the ENTER key to accept it. Press the ESCAPE key to return to the next higher level of structure. Repeat the process as required for other items.

Items in the Configuration and Service Test modes are pass- word protected. The words Enter Password will be displayed when required, with 1111 also being displayed. The default password is 0111. Use the arrow keys to change each number and press ENTER to accept the digit. Continue with the remaining digits of the password. The password can only be changed through CCN operator interface software such as ComfortWORKS®, ComfortVIEW™ and Service Tool.

Power-Up Display — When the Navigator display is powered up it will display:

ComfortLink

Navigator

By

Carrier

7

Page 7
Image 7
Carrier 30XW150-400 specifications To change the Time and Date, press the Main Menu