APPENDIX A — TOUCH PILOT™ DISPLAY TABLES (cont)

103

TOUCH PILOT DESCRIPTION

TOUCH PILOT

TOUCH PILOT PATH

LINE

READ/

CCN TABLE NAME

POINT NAME

WRITE

 

 

 

 

SCT Candidate

 

 

 

 

 

Circuit A

sct_fu_a

MAIN MENU\Maint\FANCTRL

2

RO

Maintenance Display Tables\FANCTRL

Circuit B

sct_fu_b

MAIN MENU\Maint\FANCTRL

6

RO

Maintenance Display Tables\FANCTRL

Circuit C

sct_fu_c

MAIN MENU\Maint\FANCTRL

10

RO

Maintenance Display Tables\FANCTRL

SCT Control Point

 

 

 

 

 

Circuit A

sct_sp_a

MAIN MENU\Maint\FANCTRL

1

RO

Maintenance Display Tables\FANCTRL

Circuit B

sct_sp_b

MAIN MENU\Maint\FANCTRL

5

RO

Maintenance Display Tables\FANCTRL

Circuit C

sct_sp_c

MAIN MENU\Maint\FANCTRL

9

RO

Maintenance Display Tables\FANCTRL

Slide Valve 1

 

 

 

 

 

Circuit A

Q_SLI_1A

MAIN MENU\Status\QCK_TST1

17

RW

Status Display Tables\QCK_TST1

Circuit B

Q_SLI_1B

MAIN MENU\Status\QCK_TST1

24

RW

Status Display Tables\QCK_TST1

Circuit C

Q_SLI_1C

MAIN MENU\Status\QCK_TST1

31

RW

Status Display Tables\QCK_TST1

Slide Valve 2

 

 

 

 

 

Circuit A

Q_SLI_2A

MAIN MENU\Status\QCK_TST1

18

RW

Status Display Tables\QCK_TST1

Circuit B

Q_SLI_2B

MAIN MENU\Status\QCK_TST1

25

RW

Status Display Tables\QCK_TST1

Circuit C

Q_SLI_2C

MAIN MENU\Status\QCK_TST1

32

RW

Status Display Tables\QCK_TST1

Slide Valve 1 Output

 

 

 

 

 

Circuit A

SLID_1_A

MAIN MENU\Status\CIRCA_D

3

RO

Status Display Tables\CIRCA_D

Circuit B

SLID_1_B

MAIN MENU\Status\CIRCB_D

3

RO

Status Display Tables\CIRCB_D

Circuit C

SLID_1_C

MAIN MENU\Status\CIRCC_D

3

RO

Status Display Tables\CIRCC_D

Slide Valve 2 Output

 

 

 

 

 

Circuit A

SLID_2_A

MAIN MENU\Status\CIRCA_D

4

RO

Status Display Tables\CIRCA_D

Circuit B

SLID_2_B

MAIN MENU\Status\CIRCB_D

4

RO

Status Display Tables\CIRCB_D

Circuit C

SLID_2_C

MAIN MENU\Status\CIRCC_D

4

RO

Status Display Tables\CIRCC_D

Suction Pressure

 

 

 

 

 

Circuit A

SP_A

MAIN MENU\Status\CIRCA_AN

4

RO

Status Display Tables\CIRCA_AN

Circuit B

SP_B

MAIN MENU\Status\CIRCB_AN

4

RO

Status Display Tables\CIRCB_AN

Circuit C

SP_C

MAIN MENU\Status\CIRCC_AN

4

RO

Status Display Tables\CIRCC_AN

S1 Config Switch (8 ->1)

cpa_s1_m

MAIN MENU\Maint\BOARD_PN

13

RO

Maintenance Display Tables\BOARD_PN

S1 Config Switch (8 ->1)

cpb_s1_m

MAIN MENU\Maint\BOARD_PN

17

RO

Maintenance Display Tables\BOARD_PN

S1 Config Switch (8 ->1)

cpc_s1_m

MAIN MENU\Maint\BOARD_PN

21

RO

Maintenance Display Tables\BOARD_PN

Second Setpoint in Use

Mode_02

MAIN MENU\Status\MODES

3

RO

Status Display Tables\MODES

Serial Number

SerialNo

MAIN MENU\Config\Ctlr-ID

5

RO

Configuration Tables\!CtlrID\PD5_XAXQ

Service Test Enable

Q_STREQ

MAIN MENU\Status\SERV_TST

1

RW

Status Display Tables\SERV_TST

Servicing Alert

s_alert

MAIN MENU\Service\MAINTCFG

2

RW

Service Configuration Tables\MAINTCFG

Setpoint Control

sp_ctrl

MAIN MENU\Status\GENUNIT

27

RO

Status Display Tables\GENUNIT

Setpoint Occupied?

SP_OCC

MAIN MENU\Status\GENUNIT

26

RO

Status Display Tables\GENUNIT

Setpoint select

sp_sel

MAIN MENU\Status\GENUNIT

25

RW

Status Display Tables\GENUNIT

Shutdown Indicator State

SHUTDOWN

MAIN MENU\Status\STATEGEN

27

RO

Status Display Tables\STATEGEN

Slave Address

slv_addr

MAIN MENU\Config\MST_SLV

11

RW

Configuration Tables\MST_SLV

Slave Chiller State

slv_stat

MAIN MENU\Maint\M_MSTSLV

6

RO

Maintenance Display Tables\MSTSLAVE

Slave Chiller Total Cap

slv_capt

MAIN MENU\Maint\M_MSTSLV

7

RO

Maintenance Display Tables\MSTSLAVE

Slave lagstat

lagstat

MAIN MENU\Maint\M_MSTSLV

14

RO

Maintenance Display Tables\MSTSLAVE

Slide Valve Capacity A

Q_SLIA

MAIN MENU\Status\SERV_TST

4

RW

Status Display Tables\SERV_TST

Slide Valve Capacity B

Q_SLIB

MAIN MENU\Status\SERV_TST

6

RW

Status Display Tables\SERV_TST

Slide Valve Capacity C

Q_SLIC

MAIN MENU\Status\SERV_TST

8

RW

Status Display Tables\SERV_TST

Soft Starter Select

softstar

MAIN MENU\Service\FACTORY

8

RW

Service Configuration Tables\FACTORY

Software Part Number

PartNum

MAIN MENU\Config\Ctlr-ID

3

RO

Configuration Tables\!CtlrID\PD5_XAXQ

Space T Full Reset Value

spacr_fu

MAIN MENU\Setpoint\SETPOINT

12

RW

Setpoint Configuration Tables\SETPOINT

Space T No Reset Value

spacr_no

MAIN MENU\Setpoint\SETPOINT

11

RW

Setpoint Configuration Tables\SETPOINT

Staged Loading Sequence

seq_typ

MAIN MENU\Config\USER

4

RW

Configuration Tables\USER

Start if Error Higher

start_dt

MAIN MENU\Config\MST_SLV

19

RW

Configuration Tables\MST_SLV

Startup Delay in Effect

Mode_01

MAIN MENU\Status\MODES

2

RO

Status Display Tables\MODES

Stop Pump During Standby

pump_sby

MAIN MENU\Config\USER

16

RW

Configuration Tables\USER

LEGEND

RO — Read Only

RW — Read/Write

Page 103
Image 103
Carrier 30XW150-400 specifications 103

30XW150-400 specifications

The Carrier 30XW150-400 series is a line of water-cooled chillers that exemplifies innovation, efficiency, and reliability in commercial cooling solutions. Designed for medium to large-scale applications, this series is ideal for a variety of settings, including commercial buildings, industrial processes, and chilled water systems.

One of the standout features of the Carrier 30XW series is its efficiency. The chillers utilize advanced variable-speed compressor technology, which allows the units to adapt to varying cooling loads while minimizing energy consumption. This technology not only reduces operational costs but also contributes to better environmental sustainability by lowering greenhouse gas emissions.

The 30XW series chillers are equipped with high-efficiency, scroll compressors that operate quietly and provide significant energy savings. By utilizing enhanced economizer controls, these units can achieve higher efficiency ratings, especially in part-load conditions. The result is an impressive Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), making these units a smart choice for energy-conscious businesses.

In terms of reliability, the Carrier 30XW150-400 series features robust construction and an array of safety and monitoring systems. The units come with advanced diagnostics that help in quickly identifying and addressing any operational issues. This proactive approach ensures reliability and minimizes downtime, which is crucial for maintaining optimal temperature controls in critical environments.

Additionally, the chillers incorporate environmentally friendly refrigerants that comply with the latest regulations, making them a sustainable choice for modern commercial applications. Their compact design allows for flexible installation options, and the integrated control systems provide the ability to optimize performance based on specific building management demands.

User-friendly interfaces and remote monitoring capabilities further enhance the ease of operation, allowing facility managers to have real-time insight into performance metrics and system health. This level of control contributes to better maintenance planning and maximizes the lifespan of the equipment.

In summary, the Carrier 30XW150-400 series of water-cooled chillers combines advanced technology, energy efficiency, and reliable performance, making it an ideal solution for various commercial and industrial cooling needs. With its commitment to innovation and sustainability, Carrier continues to set the standard in the HVAC industry.