APPENDIX D — 30XW150-400 CPM DIP SWITCH ADDRESSES

ACROSS-THE-LINE START — STANDARD CONDENSING

30XW

VOLTAGE

CPM DIP

 

 

 

CIRCUIT A

 

 

 

 

 

 

CIRCUIT B

 

 

 

MTA

MTA

UNIT SIZE

(3 ph, 60Hz)

SWITCHES

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

SETTING

SETTING

CIRCUIT A

CIRCUIT B

 

575

S1

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

220

220

 

S2

OFF

ON

OFF

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

ON

OFF

ON

OFF

 

 

 

 

150,325

460

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

278

278

S2

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

380

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

338

338

 

S2

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

575

S1

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

220

220

 

S2

OFF

ON

OFF

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

ON

OFF

ON

OFF

 

 

 

 

175,350

460

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

278

278

S2

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

380

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

338

338

 

S2

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

575

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

254

254

 

S2

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

200,400

460

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

314

314

S2

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

380

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

378

378

 

S2

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

 

 

 

 

ACROSS-THE-LINE START — HIGH CONDENSING/HEAT MACHINE

30XW

VOLTAGE

CPM DIP

 

 

 

CIRCUIT A

 

 

 

 

 

 

CIRCUIT B

 

 

 

MTA

MTA

UNIT SIZE

(3 ph, 60Hz)

SWITCHES

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

SETTING

SETTING

CIRCUIT A

CIRCUIT B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

282

282

 

S2

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

150,325

460

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

354

354

S2

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

380

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

426

426

 

S2

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

 

 

 

 

 

575

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

282

282

 

S2

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

175,350

460

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

354

354

S2

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

380

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

426

426

 

S2

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

 

 

 

 

 

575

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

322

322

 

S2

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

200,400

460

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

402

402

S2

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

380

S1

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

486

486

 

S2

ON

ON

OFF

ON

ON

ON

OFF

OFF

ON

ON

OFF

ON

ON

ON

OFF

OFF

 

 

 

 

LEGEND

CPM — Compressor Protection Module

DIP — Dual In-Line Package

MTA — Must Trip Amps

NOTE: Sizes 150-200 are Circuit A only.

133

Page 133
Image 133
Carrier specifications Appendix D 30XW150-400 CPM DIP Switch Addresses, 133, ACROSS-THE-LINE Start Standard Condensing

30XW150-400 specifications

The Carrier 30XW150-400 series is a line of water-cooled chillers that exemplifies innovation, efficiency, and reliability in commercial cooling solutions. Designed for medium to large-scale applications, this series is ideal for a variety of settings, including commercial buildings, industrial processes, and chilled water systems.

One of the standout features of the Carrier 30XW series is its efficiency. The chillers utilize advanced variable-speed compressor technology, which allows the units to adapt to varying cooling loads while minimizing energy consumption. This technology not only reduces operational costs but also contributes to better environmental sustainability by lowering greenhouse gas emissions.

The 30XW series chillers are equipped with high-efficiency, scroll compressors that operate quietly and provide significant energy savings. By utilizing enhanced economizer controls, these units can achieve higher efficiency ratings, especially in part-load conditions. The result is an impressive Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), making these units a smart choice for energy-conscious businesses.

In terms of reliability, the Carrier 30XW150-400 series features robust construction and an array of safety and monitoring systems. The units come with advanced diagnostics that help in quickly identifying and addressing any operational issues. This proactive approach ensures reliability and minimizes downtime, which is crucial for maintaining optimal temperature controls in critical environments.

Additionally, the chillers incorporate environmentally friendly refrigerants that comply with the latest regulations, making them a sustainable choice for modern commercial applications. Their compact design allows for flexible installation options, and the integrated control systems provide the ability to optimize performance based on specific building management demands.

User-friendly interfaces and remote monitoring capabilities further enhance the ease of operation, allowing facility managers to have real-time insight into performance metrics and system health. This level of control contributes to better maintenance planning and maximizes the lifespan of the equipment.

In summary, the Carrier 30XW150-400 series of water-cooled chillers combines advanced technology, energy efficiency, and reliable performance, making it an ideal solution for various commercial and industrial cooling needs. With its commitment to innovation and sustainability, Carrier continues to set the standard in the HVAC industry.