Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1620

PS # Input

Power source for specified

Check the AC power

 

Range

power supply is

source for the specified

 

 

unavailable, or out of

power supply. If problem

 

 

acceptable range.

persists, see

 

 

 

"Troubleshooting Power

 

 

 

Supplies" on page 139.

 

 

 

E1624

PS Redundancy The power supply

See "Troubleshooting

 

 

subsystem is no longer

Power Supplies" on

 

 

redundant. If the last

page 139.

 

 

supply fails, the system will

 

 

 

go down.

 

 

 

 

 

E1710

I/O Channel

The system BIOS has

See "Getting Help" on

 

Chk

reported an I/O channel

page 167.

 

 

check.

 

E1711 PCI PERR B##

D## F##

PCI PERR Slot

#

The system BIOS has reported a PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##.

The system BIOS has reported a PCI parity error on a component that resides in the specified PCI slot.

Remove and reseat the PCI expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 149.

Reinstall the expansion- card cage. See "Expansion- Card Cage" on page 91.

If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 167.