Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E1414 | CPU # | Specified microprocessor | See "Troubleshooting |
| Thermtrip | is out of acceptable | System Cooling Problems" |
|
| temperature range and has | on page 140. If the problem |
|
| halted operation. | persists, ensure that the |
|
|
| microprocessor heat sinks |
|
|
| are properly installed. See |
|
|
| "Troubleshooting the |
|
|
| Microprocessors" on |
|
|
| page 150. |
|
|
| NOTE: The LCD continues to |
|
|
| display this message until the |
|
|
| system’s power cord is |
|
|
| disconnected and |
|
|
| reconnected to the AC power |
|
|
| source, or the SEL is cleared |
|
|
| using either Server Assistant |
|
|
| or the BMC Management |
|
|
| Utility. See the Dell |
|
|
| OpenManage Baseboard |
|
|
| Management Controller |
|
|
| User’s Guide for information |
|
|
| about these utilities. |
|
|
|
|
E1418 | CPU # | Specified processor is | See "Troubleshooting the |
| Presence | missing or bad, and the | Microprocessors" on |
|
| system is in an | page 150. |
|
| unsupported |
|
|
| configuration. |
|
|
|
|
|
E141C | CPU Mismatch | Processors are in a | Ensure that your |
|
| configuration unsupported | processors match and |
|
| by Dell. | conform to the type |
|
|
| described in the |
|
|
| Microprocessor Technical |
|
|
| Specifications outlined in |
your system’s Getting Started Guide.
About Your System
23