Dell DL2000 owner manual E1414, Thermtrip, E1418, Presence, E141C CPU Mismatch

Models: DL2000

1 188
Download 188 pages 19.03 Kb
Page 23
Image 23

Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1414

CPU #

Specified microprocessor

See "Troubleshooting

 

Thermtrip

is out of acceptable

System Cooling Problems"

 

 

temperature range and has

on page 140. If the problem

 

 

halted operation.

persists, ensure that the

 

 

 

microprocessor heat sinks

 

 

 

are properly installed. See

 

 

 

"Troubleshooting the

 

 

 

Microprocessors" on

 

 

 

page 150.

 

 

 

NOTE: The LCD continues to

 

 

 

display this message until the

 

 

 

system’s power cord is

 

 

 

disconnected and

 

 

 

reconnected to the AC power

 

 

 

source, or the SEL is cleared

 

 

 

using either Server Assistant

 

 

 

or the BMC Management

 

 

 

Utility. See the Dell

 

 

 

OpenManage Baseboard

 

 

 

Management Controller

 

 

 

User’s Guide for information

 

 

 

about these utilities.

 

 

 

 

E1418

CPU #

Specified processor is

See "Troubleshooting the

 

Presence

missing or bad, and the

Microprocessors" on

 

 

system is in an

page 150.

 

 

unsupported

 

 

 

configuration.

 

 

 

 

 

E141C

CPU Mismatch

Processors are in a

Ensure that your

 

 

configuration unsupported

processors match and

 

 

by Dell.

conform to the type

 

 

 

described in the

 

 

 

Microprocessor Technical

 

 

 

Specifications outlined in

your system’s Getting Started Guide.

About Your System