Table
Message | Causes | Corrective Actions |
|
|
|
Error: Memory | Faulty or improperly | See "Troubleshooting |
failure detected. | seated memory module(s). | System Memory" on |
Memory size |
| page 142. |
reduced. Replace |
|
|
the faulty DIMM as |
|
|
soon as possible. |
|
|
|
|
|
!!*** Error: Dell | Dell Remote Access | Ensure that the Dell Remote |
Remote Access | Controller initialization | Access Controller is properly |
Controller | failure | installed. See "DRAC Card |
initialization |
| and Cables" on page 93. |
failure*** DRAC |
|
|
virtual USB |
|
|
devices may not be |
|
|
available... |
|
|
|
|
|
FBD training | The specified branch | Ensure that only Dell- |
error: The | (channel pair) contains | qualified memory is used. |
following branch | DIMMs that are | Dell recommends |
has been disabled: | incompatible with each | purchasing memory upgrade |
Branch x | other. | kits directly from |
|
| www.dell.com or your Dell |
|
| sales agent to ensure |
|
| compatibility. |
|
|
|
Gate A20 failure | Faulty keyboard controller; | See "Getting Help" on |
| faulty system board. | page 167. |
General failure | The operating system is |
| unable to carry out the |
| command. |
This message is usually followed by specific information. Note the information, and take the appropriate action to resolve the problem.
Invalid NVRAM | System detected and | No action is required. |
configuration, | corrected a resource |
|
Resource Re- | conflict. |
|
allocated |
|
|
|
|
|
Keyboard | Faulty keyboard controller; | See "Getting Help" on |
Controller failure | faulty system board | page 167. |
36