Dell DL2000 E2111 SBE Log, Disable Crd #, E2112 Mem Spare Crd, # Dimm ##, E2113 Mem Mirror

Models: DL2000

1 188
Download 188 pages 19.03 Kb
Page 30
Image 30

Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E2111

SBE Log

The system BIOS has

See "Troubleshooting

 

Disable Crd #

disabled memory single-bit

System Memory" on

 

DIMM ##

error (SBE) logging, and

page 142.

 

 

will not resume logging

 

 

 

further SBEs until the

 

 

 

system is rebooted. "##"

 

 

 

represents the DIMM

 

 

 

implicated by the BIOS. If

 

 

 

no memory riser card is

 

 

 

present, the "Crd #" string

 

 

 

is left out of the message.

 

 

 

 

 

E2112

Mem Spare Crd

The system BIOS has

See "Troubleshooting

 

# DIMM ##

spared the memory

System Memory" on

 

 

because it has determined

page 142.

 

 

that the memory had too

 

 

 

many errors. "## & ##"

 

 

 

represents the DIMM pair

 

 

 

implicated by the BIOS. If

 

 

 

no memory card is present,

 

 

 

the "Crd #" string is left

 

 

 

out of the message.

 

 

 

 

 

E2113

Mem Mirror

The system BIOS has

See "Troubleshooting

 

Crd # DIMM ##

disabled memory

System Memory" on

 

& ##

mirroring because it has

page 142.

 

 

determined that one half

 

 

 

of the mirror has had too

 

 

 

many errors. "## & ##"

 

 

 

represents the DIMM pair

 

 

 

implicated by the BIOS. If

 

 

 

no memory card is present,

 

 

 

the "Crd #" string is left

 

 

 

out of the message.

 

 

 

 

 

E2118

Fatal NB Mem

One of the connections in

See "Troubleshooting

 

CRC

the Fully Buffered DIMM

System Memory" on

 

 

(FBD) memory subsystem

page 142.

 

 

link on the Northbound

 

 

 

side has failed.

 

30

About Your System

Page 30
Image 30
Dell DL2000 E2111 SBE Log, Disable Crd #, E2112 Mem Spare Crd, E2113 Mem Mirror, Crd # Dimm ##, E2118 Fatal NB Mem