Message | Causes | Corrective Actions |
|
|
|
The amount of | Memory has been added or | If memory has been added |
system memory has | removed or a memory | or removed, this message is |
changed | module may be faulty. | informative and can be |
|
| ignored. If memory has not |
|
| been added or removed, |
|
| check the SEL to determine |
|
| if |
|
| errors were detected and |
|
| replace the faulty memory |
|
| module. See |
|
| "Troubleshooting System |
|
| Memory" on page 142. |
|
|
|
| Faulty battery or faulty | See "Troubleshooting the |
stopped | chip. | System Battery" on |
|
| page 138. |
|
|
|
The following DIMM | The specified DIMM(s) | Ensure that only Dell- |
pair is not | are incompatible with the | qualified memory is used. |
compatible with | system. | Dell recommends |
the memory |
| purchasing memory upgrade |
controller: DIMM x |
| kits directly from |
and DIMM y |
| www.dell.com or your Dell |
|
| sales agent to ensure |
|
| compatibility. |
|
|
|
The following | The specified DIMM(s) | Ensure that only ECC FBD1 |
DIMMs are not | are incompatible with the | memory is used. Dell |
compatible: DIMM x | system. | recommends purchasing |
and DIMM y |
| memory upgrade kits |
|
| directly from www.dell.com |
|
| or your Dell sales agent to |
|
| ensure compatibility. |
|
|
|
| Incorrect Time or Date | Check the Time and Date |
set - please run | settings; faulty system | settings. See "Using the |
SETUP program | battery. | System Setup Program" on |
|
| page 45. If the problem |
|
| persists, replace the system |
|
| battery. See "System Battery" |
|
| on page 110. |
About Your System