Table
Code | Text | Causes | Corrective Actions |
|
|
| |
E201E | POST Mem Test BIOS POST memory test | See "Troubleshooting | |
|
| failure. | System Memory" on |
|
|
| page 142. If problem |
|
|
| persists, see "Getting Help" |
|
|
| on page 167. |
E201F DRAC Config Dell remote access controller (DRAC) configuration failure.
Check screen for specific error messages.
Ensure that DRAC cables and connectors are properly seated. If problem persists, see your DRAC documentation.
E2020 | CPU Config | CPU configuration failure. | Check screen for specific |
|
|
| error messages. |
|
|
|
|
E2021 | Memory | Incorrect memory | Check screen for specific |
| Population | configuration. Memory | error messages. See |
|
| population order incorrect. "Troubleshooting System | |
|
|
| Memory" on page 142. |
|
|
| |
E2022 | POST Fail | General failure after video. Check screen for specific | |
|
|
| error messages. |
|
|
|
|
E2110 | MBE Crd # | One of the DIMMs in the | See "Troubleshooting |
| DIMM ## & ## | set implicated by "## & | System Memory" on |
|
| ##" has had a memory | page 142. |
|
|
| |
|
| no memory card is present, |
|
|
| the "Crd #" string is left |
|
|
| out of the message. |
|
About Your System
29