Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E1811 | HDD ## Rbld | The specified hard drive | See "Troubleshooting a |
| Abrt | has experienced a rebuild | Hard Drive" on page 146. |
|
| abort. | If the problem persists, see |
|
|
| your RAID |
|
|
| documentation. |
|
|
|
|
E1812 | HDD ## | The specified hard drive | Information only. |
| Removed | has been removed from |
|
|
| the system. |
|
|
|
|
|
E1913 | CPU & | The BMC firmware does | Update to the latest BMC |
| Firmware | not support the CPU. | firmware. See the BMC |
| Mismatch |
| User’s Guide for more |
|
|
| information on setup and |
|
|
| use of BMC. |
|
|
|
|
E1A11 | PCI Rsr | PCI risers are not | See |
| Config | configured correctly; some | Boards" on page 112. |
|
| invalid configurations may |
|
|
| prevent the system from |
|
|
| powering on. |
|
|
|
|
|
E1A12 | PCI Rsr | One or all of the PCI risers | Information only. |
| Missing | is missing, preventing the |
|
|
| system from powering on. |
|
E1A14 SAS Cable A SAS cable A is missing or bad.
Reseat the cable. If problem persists, replace cable. See "SAS Controller Daughter Card" on page 85.
E1A15 SAS Cable B SAS cable B is missing or bad.
Reseat the cable. If problem persists, replace cable. See "SAS Controller Daughter Card" on page 85.
E2010 No Memory | No memory is installed in |
| the system. |
Install memory. See "Installing Memory Modules" on page 102.
About Your System
27