Table
Message | Causes | Corrective Actions |
|
|
|
Alert! Redundant | Installed memory modules | Ensure that all memory |
memory disabled! | are not the same type and | modules are of the same |
Memory | size; faulty memory | type and size and that they |
configuration does | module(s). | are properly installed. If the |
not support |
| problem persists, see |
redundant memory. |
| "Troubleshooting System |
|
| Memory" on page 142. |
Attempting to | Remote Configuration |
update Remote | request has been detected |
Configuration. | and is being processed. |
Please wait... |
|
Wait until the process is complete.
BIOS Update | Remote BIOS update | Retry the BIOS update. If |
Attempt Failed! | attempt failed. | problem persists, see |
|
| "Getting Help" on page 167. |
Caution! NVRAM_CLR | NVRAM_CLR jumper is |
jumper is | installed. CMOS has been |
installed on | cleared. |
system board. |
|
Remove NVRAM_CLR jumper. See Figure
CPUs with | Microprocessors with | Ensure that all |
different cache | different cache sizes are | microprocessors have the |
sizes detected! | installed. | same cache size and that |
|
| they are properly installed. |
|
| See "Processors" on |
|
| page 105. |
|
|
|
Decreasing | Faulty or improperly | See "Troubleshooting |
available memory | installed memory modules. System Memory" on | |
|
| page 142. |
About Your System
33