Table 1-7. System Messages

Message

Causes

Corrective Actions

 

 

 

Alert! Redundant

Installed memory modules

Ensure that all memory

memory disabled!

are not the same type and

modules are of the same

Memory

size; faulty memory

type and size and that they

configuration does

module(s).

are properly installed. If the

not support

 

problem persists, see

redundant memory.

 

"Troubleshooting System

 

 

Memory" on page 142.

Attempting to

Remote Configuration

update Remote

request has been detected

Configuration.

and is being processed.

Please wait...

 

Wait until the process is complete.

BIOS Update

Remote BIOS update

Retry the BIOS update. If

Attempt Failed!

attempt failed.

problem persists, see

 

 

"Getting Help" on page 167.

Caution! NVRAM_CLR

NVRAM_CLR jumper is

jumper is

installed. CMOS has been

installed on

cleared.

system board.

 

Remove NVRAM_CLR jumper. See Figure 6-1 for jumper location.

CPUs with

Microprocessors with

Ensure that all

different cache

different cache sizes are

microprocessors have the

sizes detected!

installed.

same cache size and that

 

 

they are properly installed.

 

 

See "Processors" on

 

 

page 105.

 

 

 

Decreasing

Faulty or improperly

See "Troubleshooting

available memory

installed memory modules. System Memory" on

 

 

page 142.

About Your System

33

Page 33
Image 33
Dell DL2000 Alert! Redundant, Memory disabled, Configuration does, Not support, Redundant memory, Attempting to, Jumper is