Chapter 6 Control Modes of OperationASDA-AB Series

For example, in torque mode, if P1-41 is set to 100 and the input voltage is 10V, it indicates that the torque command is 100% rated torque. If P1-41 is set to 100, but the input voltage is changed to 5V, then the torque command is changed to 50% rated torque.

Torque command / limit = Input voltage x setting/10 (%)

6.4.5 Timing Chart of Torque Control Mode

 

T4 (P1-14)

 

 

 

 

Internal speed

T3 (P1-13)

 

 

 

 

command

 

 

 

 

T2 (P1-12)

 

 

 

 

 

 

 

 

 

External analog

 

T1

 

 

 

 

voltage or zero (0)

 

 

 

 

 

 

 

TCM0

OFF

ON

OFF

ON

External I/O signal

TCM1

OFF

 

ON

 

 

 

 

 

 

 

SON

ON

 

 

 

NOTE

1)OFF indicates normally open and ON indicates normally closed.

2)When torque control mode is Tz, the torque command T1=0; when torque control mode is T, the speed command T1 is external analog voltage input (Please refer to P1-01).

3)After Servo ON, the users can select command according to the state of TCM0~1.

Revision January 2009

6-31