P2 - 47

Chapter 7 Servo ParametersASDA-AB Series

PED

Position Deviation Clear Delay Time

Communication Addr.: 022FH

 

 

 

Default: 0

 

Related Section:

Applicable Control Mode: Pr

Section 12.6

Unit: 20ms

 

Range: 0 ~ 250

 

Settings:

 

 

This function is disabled when its setting value is set to 0.

P2 - 48

 

BLAS

Backlash Compensation of Feed Step Control

Communication Addr.: 0230H

 

 

 

 

 

 

 

 

Default: 0

 

 

 

Related Section:

Applicable Control Mode: Pr

Section 12.6

Unit: pulse

 

Range: 0 ~ 10312

 

Settings:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

A: Pulse Number Settings

0 ~ 312, the pulse number of backlash compensation

Actual pulse number of backlash compensation of motor output shaft is equal to the number of value A x electronic gear ratio

B: Polarity Settings

B=0: Forward compensation

B=1: Reverse compensation

NOTE

1)After modifying the setting value, execute the home sensor function. After executing the home sensor function, perform the control function.

Revision January 2009

7-67