Delta Electronics ASDA-AB manual Fault Messages, Display Fault Name Fault Description

Models: ASDA-AB

1 357
Download 357 pages 17.54 Kb
Page 267
Image 267

Chapter 10 TroubleshootingASDA-AB Series

 

 

 

 

Fault Messages

 

Display

Fault Name

Fault Description

 

 

 

IGBT temperature error

The temperature of IGBT is over high.

 

 

 

 

 

 

 

 

 

 

 

Memory error

EE-PROM write-in and read-out is in error.

 

 

 

 

 

 

 

 

 

 

 

DSP communication

The communication between DSP and MCU is in error. DSP do

 

 

 

 

 

 

error

not respond to MCU command. The problem is on DSP side.

 

 

 

 

 

 

 

 

 

 

 

Serial communication

RS232/485 communication is in error.

 

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

 

 

Serial communication

RS232/485 communication time out.

 

 

 

 

 

 

time out

 

 

 

 

 

 

 

 

 

 

 

 

Command write-in error

Control command write-in error.

 

 

 

 

 

 

 

 

 

 

 

Input power phase loss

One phase of the input power is loss.

 

 

 

 

 

 

 

 

 

 

 

 

To warn that the servo motor and drive is going to overload. This

 

 

 

 

alarm will display before ALM06. When the servo motor reach

 

 

 

Pre-overload warning

the setting value of P1-56, the motor will send a warning to the

 

 

 

 

drive. After the drive has detected the warning, the DO signal

 

 

 

 

OLW will be activated and this fault message will display.

 

 

 

 

 

 

 

 

Internal command

An error occurs when internal command is executing.

 

 

 

 

 

 

execution time out

 

 

 

 

 

 

 

 

 

 

 

 

DSP communication

1. DSP do not respond to MCU command.

 

 

 

2. DSP has responded to MCU command but there is error in

 

 

 

error

 

 

 

response message. Maybe the hardware is damaged.

 

 

 

 

 

 

 

 

 

 

 

 

DSP communication

1. DSP do not respond to MCU command.

 

 

 

2. DSP has responded to MCU command but there is error in

 

 

 

error

 

 

 

response message. Maybe the hardware is damaged.

 

 

 

 

 

 

 

 

 

NOTE

1)If there is any unknown fault code that is not listed on the above table, please inform the distributor or contact with Delta for assistance.

10-2

Revision January 2009

Page 267
Image 267
Delta Electronics ASDA-AB manual Fault Messages, Display Fault Name Fault Description