DO1

Digital Output Terminal 1 (DO1)

 

Communication Addr.: 0212H

 

 

 

 

 

 

Default: 101

 

Related Section:

Applicable Control Mode: ALL

 

Table 7.B

Unit: N/A

 

 

 

 

Range: 0 ~ 112

 

 

 

Settings:

This parameter is used to determine the function and status of DO1.

A

B

not used

A: DO Function Settings: For the setting value of P2- 18 ~ P2-22, please refer to Table 7.A.

B: DO Enabled Status Settings:

0:Normally closed (contact b)

1:Normally open (contact a)

Please re-start the servo drive after parameters have been changed.

P2 - 19

DO2

Digital Output Terminal 2 (DO2)

Communication Addr.: 0213H

 

 

 

Default: 103

Related Section:

Applicable Control Mode: ALL

Table 7.B

Unit: N/A

 

 

Range: 0 ~ 112

Settings: See P2-18 for explanation.

P2 - 20

DO3

Digital Output Terminal 3 (DO3)

Communication Addr.: 0214H

 

 

 

Default: 109

Related Section:

Applicable Control Mode: ALL

Table 7.B

Unit: N/A

 

 

Range: 0 ~ 112

Settings: See P2-18 for explanation.