Delta Electronics ASDA-AB manual Digital I/O

Models: ASDA-AB

1 357
Download 357 pages 17.54 Kb
Page 165
Image 165

Chapter 7 Servo ParametersASDA-AB Series

Digital I/O and relative input output setting

Digital I/O

 

 

 

 

 

 

 

Control

 

Related

 

 

Parameter

Name

Function

Default

Unit

 

Mode

 

Section of

 

 

 

 

 

 

 

User

 

 

 

 

 

 

 

Pt

Pr

S

T

 

 

 

 

 

 

 

 

 

Manual

 

 

P2-09

DRT

Bounce Filter

2

2ms

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-10

DI1

Digital Input Terminal 1 (DI1)

101

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-11

DI2

Digital Input Terminal 2 (DI2)

104

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-12

DI3

Digital Input Terminal 3 (DI3)

116

N/A

{

{

{

{

 

Table 7.A

 

 

 

 

 

 

 

 

 

 

 

 

P2-13

DI4

Digital Input Terminal 4 (DI4)

117

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-14

DI5

Digital Input Terminal 5 (DI5)

102

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-15

DI6

Digital Input Terminal 6 (DI6)

22

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-16

DI7

Digital Input Terminal 7 (DI7)

23

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-17

DI8

Digital Input Terminal 8 (DI8)

21

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-18

DO1

Digital Output Terminal 1 (DO1)

101

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-19

DO2

Digital Output Terminal 2 (DO2)

103

N/A

{

{

{

{

 

Table 7.B

 

 

 

 

 

 

 

 

 

 

 

 

P2-20

DO3

Digital Output Terminal 3 (DO3)

109

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-21

DO4

Digital Output Terminal 4 (DO4)

105

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-22

DO5

Digital Output Terminal 5 (DO5)

7

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-38

ZSPD

Zero Speed Range Setting

10

r/min

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-39

SSPD

Target Motor Speed

3000

r/min

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-42

MBT1

On Delay Time of Electromagnetic

0

ms

{

{

{

{

 

6.5.5

 

 

Brake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-43

MBT2

OFF Delay Time of Electromagnetic

0

ms

{

{

{

{

 

6.5.5

 

 

Brake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-54

PER

Positioning Completed Width

100

pulse

{

{

 

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-56

OVW

Output Overload Warning Level

120

%

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation of symbols (marked after parameter)

()

Read-only register.

(▲)

Parameter cannot be set when Servo On (when the servo drive is enabled).

(●)

Parameter is effective only after the servo drive is restarted (after switching power off and on).

(■)

Parameter setting values are not retained when power is off.

7-16

Revision January 2009