Chapter 3 Connections and WiringASDA-AB Series

 

 

 

 

 

 

 

DI

DI

Assigned

Pin No.

Details (*2)

Wiring Diagram

 

Control

 

 

 

 

 

Signal

Code

Mode

(Default)

 

(Refer to 3-3-3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JOGU

37

Not

-

Forward JOG input. When JOGU is

 

 

activated, the motor will JOG in forward

 

 

assigned

 

 

 

 

 

direction. [see P4-05]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JOGD

38

Not

-

Reverse JOG input. When JOGD is

 

 

activated, the motor will JOG in reverse

 

 

assigned

 

 

 

 

 

direction. [see P4-05]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEPU

39

Not

-

Step up input. When STEPU is activated,

 

 

assigned

the motor will run to next position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not

 

Step down input. When STEPD is

 

 

STEPD

40

-

activated, the motor will run to previous

 

 

assigned

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEPB

41

Not

-

Step back input. When STEPB is

 

 

activated, the motor will return to first

C9/C10

 

assigned

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto run input. When AUTOR is activated,

 

 

 

 

Not

 

the motor will run automatically according

 

 

AUTOR

42

-

to internal position command. For time

 

 

assigned

 

 

 

 

 

interval setting, please see P2-52 to P2-

 

 

 

 

 

 

 

 

 

 

 

 

59.

 

 

 

 

 

 

 

 

 

GNUM0

43

Not

-

Electronic gear ratio (Numerator) selection

 

 

assigned

0 [See P2-60~P2-62]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GNUM1

44

Not

-

Electronic gear ratio (Numerator) selection

 

 

assigned

1 [See P2-60~P2-62]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INHP

45

Not

-

Pulse inhibit input. When the drive is in

 

 

position mode, if INHP is activated, the

 

 

assigned

 

 

 

 

 

external pulse input command is not valid.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Footnote *2: The "state" of the input function may be turned ON or OFF as it will be dependant on the settings of P2-10~P2-17.

Revision January 2009

3-21