P2 - 63

 

 

Chapter 7 Servo ParametersASDA-AB Series

 

 

 

 

 

TSCA

Proportion Value Setting

 

Communication Addr.: 023FH

 

 

 

 

 

 

Default: 0

 

 

Related Section: N/A

Applicable Control Mode: Pt, S

Unit: times

Range: 0 ~ 11

Settings:

A

B

not used

Value A: decimal place setting of internal speed command.

0:When value A is set to 0, the unit of P1-09~P1-11 is 1 r/min (No decimal place setting)

1:When value A is set to 1, the unit of P1-09~P1-11 is 0.1 r/min (One decimal place setting) If P1-09 is set to 1234, and value A is set to 0, and then the internal speed is 1234 r/min.

If P1-09 is set to 1234, and value A is set to 1, and then the internal speed is 123.4 r/min.

This value A setting is available for internal speed command only, not available for speed limit command.

Value B: Proportion value setting of position excessive error warning condition (P2-35)

0:When value B is set to 0, the unit of P2-35 is 1 pulse

1:When value B is set to 1, the unit of P2-35 is 100 pulses

If P2-35 is set to 1000, and value B is set to 0, the position excessive error warning pulse is 1000 pulses.

If P2-35 is set to 1000, and value B is set to 1, the position excessive error warning pulse is 100,000 pulses.