Chapter 3 Connections and WiringASDA-AB Series

3.3.2 Signals Explanation of Connector CN1

The Tables 3.A, 3.B, & 3.C detail the three groups of signals of the CN1 interface. Table 3.A details the general signals. Table 3.B details the Digital Output (DO) signals and Table 3.C details the Digital Input (DI) signals. The General Signals are set by the factory and can not be changed, reprogrammed or adjusted. Both the Digital Input and Digital Output signals can be programmed by the users.

Table 3.A General Signals

Signal

Pin No

Details

Wiring Diagram

(Refer to 3-3-3)

 

 

 

 

 

V_REF

42

Motor speed command: -10V to +10V, corresponds

C1

Analog

to the maximum speed programmed P1-55

Signal

 

 

Maximum Speed Limit (Factory default 3000 RPM).

 

Input

T_REF

18

Motor torque command: -10V to +10V, corresponds

C1

 

to -100% to +100% rated torque command.

 

 

 

 

 

 

 

 

 

 

 

 

The MON1 and MON2 can be assigned drive and

 

Analog

 

 

motor parameters that can be monitored via an

 

MON1

16

analogue voltage.

 

Monitor

C2

MON2

15

Please reference parameter P0-03 for monitoring

Output

 

 

 

commands and P1-04 / P1-05 for scaling factors.

 

 

 

 

 

 

 

 

Output voltage is reference to the power ground.

 

 

 

 

 

 

 

PULSE

41

The drive can accept two different types of pulse

 

 

/PULSE

43

inputs: Open Collector and Line Driver.

C3/C4

Position

Three different pulse commands can be selected via

SIGN

37

Pulse

parameter P1-00. Quadrature , CW + CCW pulse &

 

/SIGN

36

 

Input

Pulse / Direction.

 

 

PULL HI

35

Should an Open Collector type of pulse be used this

C3

 

terminal must be lulled high to pin 17.

 

 

 

 

 

OA

21

 

 

Position

/OA

22

 

 

 

 

The motor encoder signals are available through

 

OB

25

 

Pulse

these terminals. The encoder output pulse count can

C11/C12

/OB

23

Output

be set via parameter P1-46.

 

 

 

 

OZ

50

 

 

 

 

 

/OZ

24

 

 

 

 

 

 

 

 

VDD

17

VDD is the +24V source voltage provided by the

 

 

drive. Maximum permissible current 500mA.

 

 

 

 

 

 

 

 

 

 

Power

 

11

COM+ is the common voltage rail of the Digital Input

-

COM+

45

and Digital Output signals. Connect VDD to COM+

 

 

 

for source mode. For external applied power sink

 

 

COM-

47

 

 

mode (+12V to +24V), the positive terminal should

 

 

 

49

 

 

 

be connected to COM+ and the negative to COM-.

 

 

 

 

 

 

 

 

 

VCC is a +12V power rail provided by the drive. It

 

 

VCC

20

can be used for the input on an analog speed or

 

 

torque command. Maximum permissible current

 

Power

 

 

-

 

 

100mA.

 

 

 

 

 

 

GND

12,13,

The polarity of VCC is with respect to Ground (GND).

 

 

19,44

 

 

 

 

 

 

 

 

 

 

3-16

Revision January 2009

Page 41
Image 41