Chapter 5 Trial Run and Tuning ProcedureASDA-AB Series

The settings of speed command:

P1-09 is set to 3000

Input value command

Rotation direction

P1-10 is set to 100

+

CW

 

 

 

P1-11 is set to -3000

-

CCW

 

 

 

STEP 3:

1.The users can use DI1 to enable the servo drive (Servo ON).

2.If DI3 (SPD0) and DI4 (SPD1) are OFF both, it indicates S1 command is selected. At this time, the motor is operating according to external analog command.

3.If only DI3 is ON (SPD0), it indicates S2 command (P1-09 is set to 3000) is selected, and the motor speed is 3000r/min at this time.

4.If only DI4 is ON (SPD1), it indicates S3 command (P1-10 is set to 100) is selected, and the motor speed is 100r/min at this time.

5.If DI3 (SPD0) and DI4 (SPD1) are ON both, it indicates S4 command (P1-11 is set to -3000) is selected, and the motor speed is -3000r/min at this time.

6.Repeat the action of (3), (4), (5) freely.

7.When the users want to stop the speed trial run, use DI1 to disable the servo drive (Servo OFF).

5-10

Revision January 2009

Page 87
Image 87
Delta Electronics ASDA-AB manual Ccw