Chapter 9 Maintenance and InspectionASDA-AB Series

Item

Content

 

 

 

z Ensure that the cables are not damaged, stressed excessively or loaded heavily.

 

When the motor is running, pay close attention on the connection of the cables

 

and notice that if they are damaged, frayed or over extended.

 

z Check for abnormal vibrations and sounds during operation. If the servo motor is

 

vibrating or there are unusual noises while the motor is running, please contact

 

the dealer or manufacturer for assistance.

Inspection during

z Ensure that all user-defined parameters are set correctly. Since the

characteristics of various machinery are different, in order to avoid accident or

operation

cause damage, do not adjust the parameter abnormally and ensure the

(Control power is

parameter setting is not an excessive value.

applied)

z Ensure to reset some parameters when the servo drive is off (Please refer to

 

Chapter 7). Otherwise, it may result in malfunction.

 

z If there is no contact sound or there be any unusual noises when the relay of the

 

servo drive is operating, please contact your distributor for assistance or contact

 

with Delta.

 

z Check for abnormal conditions of the power indicators and LED display. If there is

 

any abnormal condition of the power indicators and LED display, please contact

 

your distributor for assistance or contact with Delta.

 

 

9.2Maintenance

„Use and store the product in a proper and normal environment.

„Periodically clean the surface and panel of servo drive and motor.

„Make sure the conductors or insulators are corroded and/or damaged.

„Do not disassemble or damage any mechanical part when performing maintenance.

„Clean off any dust and dirt with a vacuum cleaner. Place special emphasis on cleaning the ventilation ports and PCBs. Always keep these areas clean, as accumulation of dust and dirt can cause unforeseen failures.

9.3Life of Replacement Components

„Smooth capacitor

The characteristics of smooth capacitor would be deteriorated by ripple current affection. The life of smooth capacitor varies according to ambient temperature and operating conditions. The common guaranteed life of smooth capacitor is ten years when it is properly used in normal air-conditioned environment.

„Relay

The contacts will wear and result in malfunction due to switching current. The life of relay varies according to power supply capacity. Therefore, the common guaranteed life of relay is cumulative 100,000 times of power on and power off.