Chapter 7 Servo ParametersASDA-AB Series

Basic Parameters

 

 

 

 

 

 

 

Control

 

Parameter

Name

Function

Default

Unit

 

 

 

Mode

 

 

 

 

 

 

 

Pt

 

Pr

S

T

 

P1-43

MBT2

OFF Delay Time of Electromagnetic

0

ms

{

{

{

{

 

Brake

 

 

 

 

 

 

 

 

 

 

 

 

P1-44▲

GR1

Electronic Gear Ratio (1st Numerator)

1

pulse

{

{

 

 

 

(N1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-45▲

GR2

Electronic Gear Ratio (Denominator)

1

pulse

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-46▲

GR3

Encoder Output Pulse Number

1

pulse

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

P1-47

HMOV

Homing Mode

00

N/A

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-48

HSPD1

1st Speed Setting of High Speed

1000

r/min

{

{

{

{

 

Homing

 

 

 

 

 

 

 

 

 

 

 

 

P1-49

HSPD2

2nd Speed Setting of Low Speed

50

r/min

{

{

{

{

 

Homing

 

 

 

 

 

 

 

 

 

 

 

 

P1-50

HOF1

Homing Offset Rotation Number

0

rev

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

P1-51

HOF2

Homing Offset Pulse Number

0

pulse

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

P1-52

RES1

Regenerative Resistor Value

N/A

Ohm

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

P1-53

RES2

Regenerative Resistor Capacity

N/A

Watt

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

P1-54

PER

Positioning Completed Width

100

pulse

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-55

MSPD

Maximum Speed Limit

rated speed

r/min

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

P1-56

OVW

Output Overload Warning Level

120

%

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-57

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-58

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-59

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-60

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-61

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-62

COKT

Delay Time of Internal Position

0

ms

 

 

 

{

 

 

 

Command Completed Output Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation of symbols (marked after parameter)

()

Read-only register.

(▲)

Parameter cannot be set when Servo On (when the servo drive is enabled).

(●)

Parameter is effective only after the servo drive is restarted (after switching power off and on).

(■)

Parameter setting values are not retained when power is off.

7-4

Revision January 2009

Page 153
Image 153
Delta Electronics ASDA-AB manual Control, Parameter Name Function Default Unit Mode