Delta Electronics ASDA-AB manual Zspd, Sspd

Models: ASDA-AB

1 357
Download 357 pages 17.54 Kb
Page 190
Image 190

P1 - 38

 

 

Chapter 7 Servo ParametersASDA-AB Series

 

 

 

 

 

ZSPD

Zero Speed Range Setting

 

Communication Addr.: 0126H

 

 

 

 

 

 

Default: 10

 

Related Section: N/A

Applicable Control Mode: ALL

Unit: r/min

Range: 0 ~ 200

Settings:

This parameter is used to set output range of zero speed signal (ZSPD).

ZSPD is activated when the drive senses the motor is equal to or below the Zero Speed Range setting as defined in parameter P1-38.

For Example, at default ZSPD will be activated when the drive detects the motor rotating at speed at or below 10 r/min. ZSPD will remain activated until the motor speed increases above 10 r/min.

P1 - 39

SSPD

Target Motor Speed

Communication Addr.: 0127H

 

 

 

Default: 3000

Related Section: N/A

Applicable Control Mode: ALL

Unit: r/min

Range: 0 ~ 5000

Settings:

When target motor speed reaches its preset value, digital output (TSPD) is enabled. When the forward and reverse speed of servo motor is equal and higher than the setting value, the motor will reach the target motor speed, and then TSPD signal will output.

TSPD is activated once the drive has detected the motor has reached the Target Motor Speed setting as defined in parameter P1-39. TSPD will remain activated until the motor speed drops below the Target Motor Speed.